- 9 - 

commercial switches—decreasing the possible loss caused by network 
failures in an industrial setting. 
There are 4 Hardware DIP Switches for Turbo Ring on the top panel of the 
EDS-405A-PTP that can be used to set up the Turbo Ring easily within 
seconds. If you do not want to use a hardware DIP switch to set up Turbo 
Ring, you can use a web browser, Telnet, or console to disable this 
function. 

NOTE  Refer to the 

Turbo Ring DIP Switch

 section and 

Using 

Communication Redundancy

 section in the user’s manual for 

detailed information about the settings and usage of 

Turbo Ring

 

and 

Turbo Ring V2

 

EDS-405A-PTP Series DIP Switches 

 

The default setting for each DIP Switch is OFF. The 
following table explains the effect of setting the DIP 
Switch to the ON position. 

 
“Turbo Ring” DIP Switch Settings 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

Reserved for 
future use. 

ON: Enables this 
EDS as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” ports. 

ON: Activates 
DIP switches 1, 2, 
3 to configure 
“Turbo Ring” 
settings. 

OFF: This EDS 
will not be the 
Ring Master. 

OFF: Do not use 
this EDS as the 
ring coupler. 

OFF: DIP 
switches 1, 2, 3 
will be disabled. 

 
“Turbo Ring V2” DIP Switch Settings   

DIP 1 

DIP 2 

DIP 3 

DIP 4 

ON: Enables the 
default “Ring 
Coupling 
(backup)” port. 

ON: Enables this 
EDS as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” port. 

ON: Activates 
DIP switches 1, 
2, 3 to configure 
“Turbo Ring V2” 
settings. 

OFF: Enables the 
default “Ring 
Coupling 
(primary)” port. 

OFF: This EDS 
will not be the 
Ring Master. 
 

OFF: Do not use 
this EDS as a ring 
coupler. 

OFF: DIP 
switches 1, 2, 3 
will be disabled. 

 

NOTE  If you do not enable any of the EDS-405A-PTP switches to be the 

Ring Master, the Turbo Ring protocol will automatically choose 
the EDS-405A-PTP with the smallest MAC address range to be the 
Ring Master. If you accidentally enable more than one 
EDS-405A-PTP to be the Ring Master, these EDS-405A-PTP 
switches will auto-negotiate to determine which switch will be the 
Ring Master. 

 

 

Summary of Contents for EtherDevice EDS-405A-PTP Series

Page 1: ...2014 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802004050010 EDS 405A PTP Series Hardware Installation Guide Moxa EtherDevice Switch First Edition July 2014...

Page 2: ...ed SCADA control network Package Checklist The Moxa EDS 405A PTP switches are shipped with the following items If any of these items is missing or damaged please contact your customer service represen...

Page 3: ...output 2 System state LED 3 Power input 1 LED 4 Power input 2 LED 5 Fault LED 6 MSTR HEAD LED 7 CPLR TAIL LED 8 10 100BaseT X ports 9 Model name 10 Reset button 11 Grounding screw 12 Console port 13...

Page 4: ...4 Mounting Dimensions unit mm Unit mm inch...

Page 5: ...nel and then attach the wall mount plates with M3 screws as shown in the diagram at the right STEP 2 Mounting the EDS 405A PTP on the wall requires 4 screws Use the switch with wall mount plates attac...

Page 6: ...transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Keep input wiring a...

Page 7: ...egative positive DC wires into the V V terminals respectively STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the ter...

Page 8: ...This will cause the STATE LED to blink once a second After depressing the button for 5 continuous seconds the STATE LED will start to blink rapidly This indicates that factory default settings have be...

Page 9: ...he Ring Master ON Enables the default Ring Coupling ports ON Activates DIP switches 1 2 3 to configure Turbo Ring settings OFF This EDS will not be the Ring Master OFF Do not use this EDS as the ring...

Page 10: ...nput PWR1 Off Power is not being supplied to power input PWR1 PWR2 AMBER On Power is being supplied to power input PWR2 Off Power is not being supplied to power input PWR2 FAULT RED On 1 The signal co...

Page 11: ...X function allows users to connect the EDS 405A PTP s 10 100BaseTX ports to any kind of Ethernet device without needing to pay attention to the type of Ethernet cable being used for the connection Th...

Page 12: ...ture 10 to 60C 14 to 140F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B...

Reviews: