Moxa Technologies EtherDevice EDR-G902 Quick Installation Manual Download Page 9

- 9 - 

RJ45 (10-pin) to DB9 (F) Cable Wiring 

 

10/100/1000BaseT(X) Ethernet Port Connection 

The 10/100/1000BaseT(X) ports located on Moxa EtherDevice Router’s 
front panel are used to connect to Ethernet-enabled devices. Most users 
will choose to configure these ports for Auto MDI/MDI-X mode, in which 
case the port’s pinouts are adjusted automatically depending on the type 
of Ethernet cable used (straight-through or cross-over), and the type of 
device (NIC-type or HUB/Switch-type) connected to the port. 
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X 
(HUB/Switch-type) ports. We also give cable wiring diagrams for 
straight-through and cross-over Ethernet cables. 

10/100Base T(x) RJ45 Pinouts 

MDI Port Pinouts 

MDI-X Port Pinouts 

8-pin RJ45 

Pin 

Signal 

Tx+ 

Tx- 

Rx+ 

Rx- 

 

Pin 

Signal 

Rx+ 

Rx- 

Tx+ 

Tx- 

 

 

 

1000BaseT RJ45 Pinouts 

Pin 

MDI 

MDI-X 

BI_DA+ 

BI_DB+ 

BI_DA- 

BI_DB- 

BI_DB+ 

BI_DA+ 

BI_DC+ 

BI_DD+ 

BI_DC- 

BI_DD- 

BI_DB- 

BI_DA- 

BI_DD+ 

BI_DC+ 

BI_DD- 

BI_DC- 

 

 

 

 

 

Summary of Contents for EtherDevice EDR-G902

Page 1: ...9030016 1802009030016 EDR G902 G903 Series Quick Installation Guide Moxa EtherDevice Router Version 6 1 January 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights...

Page 2: ...ndows utility Quick installation guide printed Warranty card Features Advanced Industrial Networking Capability Router Firewall VPN all in one High performance Gigabit copper fiber combo port Supports...

Page 3: ...5 Fault LED 6 VRRP Master LED 7 VPN LED 8 10 100 1000BaseT X LED indicator 9 LED for DMZ WAN2 port 10 RESET button for factory default EDR G902 Front Panel 1 WAN LAN port 10 100 1000 BaseT X or 100 1...

Page 4: ...l 1 Grounding screw 2 4 pin terminal block for PWR 1 PWR 2 3 4 pin terminal block for DI and Relay 4 RS 232 console port 5 Reset button Rear Panel 1 Terminal block 2 DIN Rail kit Mounting Dimensions U...

Page 5: ...Router from the DIN Rail simply reverse Steps 1 and 2 above Wiring Requirements WARNING Do not disconnect modules or wires unless power has been switched off or the area is known to be non hazardous...

Page 6: ...uit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to determine which wires should be kept sepa...

Page 7: ...The two wires attached to the fault contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Wiring the Redund...

Page 8: ...minal block receptor which is located on the EDR G903 s top panel Communication Connections Each EtherDevice Router has 2 types of communication port 1 1 RJ45 console port RS 232 interface 2 3 combina...

Page 9: ...le used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type po...

Page 10: ...es I and II Unlike electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and t...

Page 11: ...n When a user configured event is triggered Off When a user configured event has not been triggered 10 100 1000M AMBER On TP or FX port s 10 100 Mbps link is active Blinking Data is being transmitted...

Page 12: ...30 V For state 0 30 to 3 V Max input current 8 mA Power Input Voltage 12 24 48 VDC redundant dual inputs Connection Removable terminal block Overload Current Protection Present Reverse Polarity Prote...