- 6 -
STEP 3:
Once the screws are fixed in the
wall, insert the four screw heads
through the large parts of the
keyhole-shaped apertures, and then
slide the EDS downwards, as
indicated. Tighten the four screws
for added stability.
ATEX Information
1.
Certificate number DEMKO 10 ATEX 0917324X
2.
Ambient range (-40°C ≤ Tamb ≤ 75°C)
3.
Certification string (Ex nA nC IIC T4 Gc)
4.
Standards covered (EN 60079-0:2012, EN 60079-15:2010)
5.
The conditions of safe usage:
•
Subject devices are for use in ambient temperature -40°C
≤Tamb ≤ +75°C.
•
Subject devices are to be installed in an IP54 enclosure.
•
Subject devices are for use in an area of not more than pollution
degree 2 in accordance with IEC 60664-1.
•
Subject devices are to use Conductors suitable for use in an
ambient temperature of 100°C must be used for the Power
Supply Terminal.
Wiring Requirements
WARNING
Safety First!
Turn the power off before disconnecting modules or wires. The
proper power supply voltage is listed on the product label. Check
the voltage of your power source to make sure you are using the
correct voltage. Do NOT use a voltage greater than what is
specified on the product label.
These devices must be supplied by an AELV source as defined in
the Low Voltage Directive 2006/95/EC and 2004/108/EC.
WARNING
Safety First!
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.