background image

 

- 16 - 

Power 
Input Voltage 

EDS-405A/408A: 
12 to 45 VDC, redundant inputs 
EDS-408A-3S-SC-48: 
±24/±48 VDC (-60 to -19 VDC or 19 to 60 
VDC), redundant inputs (The mixing of 
power polarity system is prohibited.) 

Input Current (@ 24 V) 

EDS-405A: Max. 0.24 A 
EDS-408A: Max. 0.21 A 
EDS-405A-MM, EDS-405A-SS: Max. 0.32 A 
EDS-408A-MM, EDS-408A-SS: Max. 0.26 A 
EDS-408A-3M/3S/2M1S/1M2S: Max. 0.32 A 

Connection 

One removable 6-pin terminal block 

Overload Current Protection Present 
Reverse Polarity Protection  Present 
Physical Characteristics 
Housing 

Metal, IP30 protected 

Dimensions   

53.6 

×

 135 

×

 105 mm 

Weight   

0.65 kg (EDS-405A models) 
0.89 kg (EDS-408A models) 

Installation   

DIN-Rail, Wall Mounting (optional kit) 

Environmental Limits 
Operating Temperature 

0 to 60°C (32 to 140°F); 
-40 to 75°C (-40 to 167°F ) for -T models 

Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative Humidity  5% to 95% (non-condensing) 
Regulatory Approvals 
Safety 

EDS-405A/408A: UL 60950-1, UL 508, CSA 
C22.2 No. 60950-1, EN 60950-1 
EDS-408A-3S-SC-48: UL508 (Pending) 

Hazardous Location 

UL/cUL Class I, Division 2, Groups A, B, C 
and D 
ATEX Zone 2 :   
EDS-405A:Ex nC nL IIC T4 
EDS-408A: EX nA nC op is IIC T4 Gc 

EMI 

FCC Part 15, CISPR (EN 55022) class A 

EMS 

EN 61000-4-2 (ESD), Level 3 
EN 61000-4-3 (RS), Level 3 
EN 61000-4-4 (EFT), Level 3 
EN 61000-4-5 (Surge), Level 3 
EN 61000-4-6 (CS), Level 3 

Shock 

IEC 60068-2-27 

Freefall 

IEC 60068-2-32 

Vibration 

IEC 60068-2-6 

WARRANTY 

5 years 

 
 

 

Summary of Contents for EDS-405A

Page 1: ... 2014 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802004000018 EDS 405A 408A Series Hardware Installation Guide Moxa EtherDevice Switch Ninth Edition December 2014 ...

Page 2: ...of your Ethernet network Package Checklist The Moxa EDS 405A 408A switches are shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance EDS 405A or EDS 408A Ethernet switch RJ45 to DB9 console port cable Protective caps for unused ports Panel mounting kit optional must order separately Hardware installation guid...

Page 3: ...output 3 Heat dissipation vents 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 TP port s 100 Mbps LED 12 TP port s 10 Mbps LED 13 Model Name 14 10 100BaseT X ports 15 Screw hole for wall mounting kit 16 DIN Rail kit ...

Page 4: ... screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation vents 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 TP port s 100 Mbps LED 12 TP port s 10 Mbps LED 13 Model Name 14 10 100BaseT X ports 15 100BaseFX ports 16 FX port s 100 Mbps LEDs 17 Screw hole for wall mounting k...

Page 5: ...ion vents 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 TP port s 100 Mbps LED 12 TP port s 10 Mbps LED 13 Model Name 14 10 100BaseT X ports 15 100BaseFX ports 16 FX port s 100 Mbps LEDs 17 Screw hole for wall mounting kit 18 DIN Rail kit ...

Page 6: ...2 and relay output 3 Console port 4 DIP switches 5 Heat dissipation vents 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 10 100BaseT X ports 12 TP port s 100 Mbps LED 13 TP port s 10 Mbps LED 14 100BaseFX ports 15 1 FX port s 100Mbps LEDs 100M M multi mode FX port 100M S single mode FX port 16 Model Name 17 Screw hole for wall moun...

Page 7: ... 7 Mounting Dimensions unit mm Unit mm inch ...

Page 8: ...panel and then attach the wall mount plates with M3 screws as shown in the diagram at the right STEP 2 Mounting the EDS 405A 408A on the wall requires 4 screws Use the switch with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the fig...

Page 9: ...ent goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read and follow these important guidelines Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through...

Page 10: ...8A is the Master of this Turbo Ring and the Turbo Ring is broken OR There is a start up failure If none of these three conditions is satisfied the fault circuit will remain closed Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 6 contact terminal block connector on the EDS 405A 408A s top panel are used for the EDS 405A 408A s two DC inputs Top and front v...

Page 11: ...r straight through and cross over Ethernet cables 10 100Base T x RJ45 Pinouts MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring RJ45 8 pin to RJ45 8 pin Cross Over Cable Wiring 100BaseFX Ethernet Port Connection The concept behind the SC ST port and cable is quite straightforward Suppo...

Page 12: ...ts as a backup and automatically supplies the EDS 405A 408A with power Relay Contact The Moxa EtherDevice switch has one relay contact located on the top panel For detailed instructions on how to connect the relay contact power wires to the two middle contacts of the 6 contact terminal block connector see the Wiring the Relay Contact section A typical scenario would be to connect the fault circuit...

Page 13: ... in the user s manual for detailed information about the settings and usage of Turbo Ring and Turbo Ring V2 EDS 405A 408A Series DIP Switches The default setting for each DIP Switch is OFF The following table explains the effect of setting the DIP Switch to the ON position Turbo Ring DIP Switch Settings DIP 1 DIP 2 DIP 3 DIP 4 Reserved for future use ON Enables this EDS as the Ring Master ON Enabl...

Page 14: ... not being supplied to power input PWR2 FAULT RED On When 1 a relay warning event is triggered 2 the EDS 405A 408A is the Master of this Turbo Ring and the Turbo Ring is broken or 3 start up failure Off When a relay warning event is not triggered MSTR HEAD GREEN On When the EDS 405A 408A is set as the Master of the Turbo Ring or as the Head of the Turbo Chain Blinking The EDS 405A 408A has become ...

Page 15: ...RARP RMON HTTP Telnet Syslog DHCP Option 66 67 82 BootP LLDP Modbus TCP IPv6 MIB MIB II Ethernet Like MIB P BRIDGE MIB RMON MIB Group 1 2 3 9 Bridge MIB RSTP MIB Forwarding and Filtering Rate 148810 pps Processing Type Store and Forward Flow Control IEEE802 3x flow control back pressure flow control Interface RJ45 Ports 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connec...

Page 16: ...dels 0 89 kg EDS 408A models Installation DIN Rail Wall Mounting optional kit Environmental Limits Operating Temperature 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety EDS 405A 408A UL 60950 1 UL 508 CSA C22 2 No 60950 1 EN 60950 1 EDS 408A 3S SC 48 UL508 Pending Hazar...

Page 17: ...icas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 ...

Reviews: