background image

 

 

P/N: 1802040140010 

*1802040140010* 

EDS-4014 Series   

Quick Installation Guide 

Moxa EtherDevice™ Switch 

Version 1.0, March 2022 

Technical Support Contact Information 

www.moxa.com/support 

 

 

 

 

 

 

 

 

 

 

 

 2022 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for EDS-4014 Series

Page 1: ...02040140010 1802040140010 EDS 4014 Series Quick Installation Guide Moxa EtherDevice Switch Version 1 0 March 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights re...

Page 2: ...nt product pages located on Moxa s website www moxa com Default Settings IP address 192 168 127 253 Subnet Mask 255 255 255 0 Username admin Password moxa Panel Views of EDS 4014 Series Front Panel Vi...

Page 3: ...3 Bottom Panel View 1 microSD card slot currently disabled 2 Reset button 3 DIP switches for Turbo Ring Ring Master and Ring Coupler Mounting Dimensions...

Page 4: ...rt the upper lip of the DIN rail into the DIN rail mounting kit STEP 2 Press the EDS device towards the DIN rail until it snaps into place Removal STEP 1 Pull down the latch on the mounting kit with a...

Page 5: ...6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on at right NOTE Before tightening the screws into the wall make sure the screw head and shank size are...

Page 6: ...um current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read and follow these important poin...

Page 7: ...esponding pin type cable terminals NOTE The wire must be able to withstand at least 105 C and the torque value should be 4 5 lb in 0 51 N m NOTE We suggest the length of the pin type cable terminal is...

Page 8: ...dels products there are two power inputs for redundancy for the high voltage HV models products there is only one power input Refer to the instructions and diagram below on how to connect the wires to...

Page 9: ...er to tighten the wire clamp button on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on the EDS...

Page 10: ...TS 8 DTR USB Connection NOTE The USB function is currently reserved and may be required in the future It should be noted that this port cannot be used for charging any devices 10 100BaseT X Ethernet P...

Page 11: ...ntrary to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and the other...

Page 12: ...aged redundant Ethernet switches The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 5...

Page 13: ...ches to be the Ring Master the Turbo Ring protocol will automatically choose the EDS switch with the smallest MAC address range to be the Ring Master If you accidentally enable more than one switch to...

Page 14: ...switch has become the Master of Turbo Ring after Turbo Ring has gone down 2 The switch is set as Head of Turbo Chain and Turbo Chain has gone down 3 The switch is set as the Turbo Ring s Member and th...

Page 15: ...nking 4 times sec When the port s data is being transmitted at 10 100Mbps Off When the port is inactive or link down 100M 1000M SFP port Green On When the port is active and links at 1 000Mbps Blinkin...

Page 16: ...ifferent power module refer to the specifications of the corresponding model For example if you replace the power module of the EDS 4014 LV T with the PWR 105 HV I refer to the specifications of the E...

Page 17: ...Safety UL 61010 2 201 EN 62368 1 LVD EMC EN 55022 24 EN 61000 6 2 6 4 EMI FCC Part 15 Subpart B Class A EMS EN 61000 4 2 ESD Level 4 EN 61000 4 3 RS Level 3 EN 61000 4 4 EFT Level 4 EN 61000 4 5 Surg...