- 13 -
DIP Switch Settings
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
Reserved
for future
use
ON:
Enables the
default “Ring
Coupling
(backup)” port
when DIP switch 4
is already enabled.
ON:
Enables
this EDS as
the Ring
Master.
ON:
Enables the
default
“Ring
Coupling”
port.
ON:
Activates
DIP switch 2,
3, and 4 to
configure
Turbo Ring V2
settings.
OFF:
Enables the
default Ring
Coupling
(primary) port
when DIP switch 4
is already enabled.
OFF:
This
EDS will not
be the Ring
Master.
OFF:
This
EDS will not
be the Ring
Coupler.
OFF:
DIP
switch 2, 3,
and 4 will be
disabled.
NOTE
You must enable the
Turbo Ring
(DIP switch 5) first before
using the DIP switch to activate the Master and Coupler
functions.
NOTE
If you do not enable any of the EDS switches to be the Ring
Master, the Turbo Ring protocol will automatically choose the
EDS switch with the smallest MAC address range to be the Ring
Master. If you accidentally enable more than one switch to be
the Ring Master, these switches will auto-negotiate to
determine which one will be the Ring Master.
LED Indicators
The front panel of the Moxa EDS-4014 Series contains several LED
indicators. The function of each LED is described in the following table:
Device LED Indicators
LED
Color
State
Description
STATE
Green
On
When system has passed power-
on self-test (POST) and is ready
to run.
Blinking
(1 time/sec)
Press the reset button for five
seconds to reset to factory
default settings
Blinking
(4 times/sec)
When pressing the reset button
depress for 5 seconds to reset to
factory default.
Off
N/A
Red
On
The system has initially failed
the boot-up process
•
System Info. Read Fail or
EEPROM information error