Wiring the Redundant Power Inputs
The EDR-G9010 Series has two sets of power inputs—power input 1
and power input 2. The top and side views of the terminal block
connector are shown below.
Top View
Right View
STEP 1:
Use a small flat-blade screwdriver
to press a wire locker.
STEP 2:
Insert a positive/negative DC wire
into the V+/V-
terminals
respectively.
STEP 3:
Release the wire locker, and check
whether the wire is fixed.
The input terminal block (TB1) should be installed using 16-24 AWG
wires.
The power cord adapter should be connected to a socket outlet with an
earthing connection. The power cord and adapter must comply with
Class II construction.
This product is intended to be supplied by a UL Listed Power Adapter or
DC power source marked ‘L.P.S’ or ‘Limited Power Source’, rated 12 to
48 VDC, 1.51 A (min.), and Tma 75°C (min.). If you require further
assistance, please contact your Moxa representative.
Communication Connections
Each EDR-G9010 Series has three types of communication ports:
•
1 Type-C console port (RS-232 interface, baudrate: 115200, 8-N-1)
•
8 10/100/1000BaseT(X) Ethernet ports
•
2 1G/2.5G SFP ports
TYPE-C Console Port Connection
The EDR-G9010 Series provides one Type-C console port located on the
top panel. Connect the industrial secure router to a PC COM port using
the Type-C-to-DB9 connection cable, and then launch a console
terminal software, e.g. Moxa PComm Terminal Emulator, to access the
EDR-G9010 Series’ console configuration utility.
TYPE-C-to-DB9 Cable Wiring
P1
P2
2
A5 BROWN
B5 GREEN
3
A6 RED