Firmware Recovery
When the LEDs of FAULT, Signal Strength, CLIENT, BRIDGE and WLAN all light up simultaneously and
blink at one-second interval, it means the system booting has failed. It may result from some wrong operation
or uncontrollable issues, such as an unexpected shutdown during firmware update. The AWK-3131-RCC is
designed to help administrators recover such damage and resume system operation rapidly. You can refer to
the following instructions to recover the firmware:
Connect to the AWK-3131-RCC’s ES-232 console with 115200bps and N-8-1. You will see the following
message shown on the terminal emulator every one second.
Press Ctrl - C and the following message will appear.
Enter 2 to change the network setting. Specify where the AWK-3131-RCC’s firmware file on the TFTP server
and press y to write the settings into flash memory.
AWK-3131-RCC restarts, and the “Press Ctrl-C to enter Firmware Recovery Process…” message will reappear.
Press Ctrl-C to enter the menu and select 1 to start the firmware upgrade process.