background image

Summary of Contents for EdaMove 3

Page 1: ...User Manual EdaMove 3 EDA and Physical Activity Sensor Bedienungsaneitung...

Page 2: ...ion of the User Manual can be found here https www movisens com wp content downloads EdaMove3_User_Manual pdf Frequently asked questions https www movisens com en faq movisens GmbH Augartenstra e 1 76...

Page 3: ...Internet www movisens com E Mail support movisens com Copyright movisens GmbH...

Page 4: ...6 Software Installation 17 6 1 System Requirements 17 6 2 Installing the Software 18 6 3 Updating the Software 20 6 4 Updating the Sensor Firmware 20 6 5 Uninstalling the Software 21 7 Handling 23 7 1...

Page 5: ...intenance 47 8 2 Cleaning Instructions 47 8 3 Cleaning the electrodes 47 8 4 Cleaning of Wrist Bands 47 8 5 Proper Disposal 48 8 6 Troubleshooting 48 9 Technical Data 50 10 Legal Notes 53 10 1 Copyrig...

Page 6: ......

Page 7: ...iological parameters in everyday life Please read this manual completely and thoroughly before bringing the measurement system into service In this manual you will find the relevant information about...

Page 8: ......

Page 9: ...atic measurement method applying a DC voltage of 0 5V to the skin to acquire skin conductance To measure the physical activity of a person the sensor acquires the 3D acceleration and the atmospheric a...

Page 10: ...ion to long term data recording and offline processing the EdaMove 3 can transmit a live analysis of EDA data and physical activity parameters via Bluetooth Smart When connected to the Sensor Trigger...

Page 11: ...0 Hz Temp mean 1 30 Hz Movement Acceleration 1 30 Hz Step Count Step count 1 30 Hz charging 1 10 Hz whether the device is being charged State of charge 1 60 Hz the current battery level These values a...

Page 12: ......

Page 13: ...d by the manufacturer The EdaMove 3 is not waterproof Don t use the sensor in wet environments Only use the EdaMove 3 under the specified conditions Only use USB standard compatible devices to charge...

Page 14: ......

Page 15: ...red to perform measurements in addition to the scope of delivery 4 1 Scope of Delivery The following component is included in delivery Article Order No EdaMove 3 EDA and Activity Sensor Raw data acqui...

Page 16: ...Wrist Measurement 15 to 18 cm 10130 Wrist Band Move 3 L Size L Wrist Measurement 17 to 23 cm 10131 Wrist Band Move 3 XL Size XL Wrist Measurement 20 to 28 cm 10132 USB Charger USB Charger for 110 240...

Page 17: ...ser Licence Basic Software with Algorithms for Physical Activity 20100 DataAnalyzer Module EnergyExpenditure Single User Licence in combination with DataAnalyzer Base Algorithms for Energy Expenditure...

Page 18: ...Sampling for Android Bundle license for 1 000 000 item results usable with unlimited number of smartphones 20112 Sensor Trigger Solution for Interactive Ambulatory Assessment to retrieve the sensor da...

Page 19: ...ed data The experience sampling platform movisensXS for interactive ambulatory assessment The SensorTrigger application allows the EdaMove 3 to transmit various parameters to an Android smartphone The...

Page 20: ...l tradeoff between exact determination of skin conductance reaction timing and preserving memory and battery The EdaMove 3 comes equipped with reusable non polarizing sintered Ag AgCl electrodes reces...

Page 21: ...required it can be deactivated by installing a different firmware See 6 4 A cradle with a micro USB interface comes included in the delivery To connect the sensor to a PC you have to remove the sensor...

Page 22: ...harging Flashing yellow The sensor is active records data It is connected to a charger The battery is fully charged Flashing blue fast three times per second The battery level is low the sensor will t...

Page 23: ...on hard disc The included software consists of two programs SensorManager A program that allows you to configure the sensor to start a measurement and to extract the data from the sensor UnisensViewe...

Page 24: ...ve into the USB port of your PC The content of the medium will be shown If the window does not open automatically select the appropriate drive from the window My computer Step 2 Double click the file...

Page 25: ...19 6 The Installation runs automatically in the background After a successful installation a shortcut UnisensViewer is created in the Windows Start Menu...

Page 26: ...e Windows Start Menu The use of the different programs is explained in the DataAnalyzer User Manual 6 3 Updating the Software You need an internet connection to update the software Select Windows Star...

Page 27: ...f the sensor allowing customized applications or to deactivate the Bluetooth interface in order to extend battery life These firmware versions are available upon request from movisens To install the n...

Page 28: ......

Page 29: ...or to a test person Furthermore you get information on how to save delete and analyze data from the sensor A typical usage scenario for the assessment of data and offline analysis is shown in the foll...

Page 30: ...e the sensor in combination with the experience sampling platform movisensXS the different steps to use the sensor are shown in the following figure Unlike the offline measurement the measurement is i...

Page 31: ...25 7 To retrieve the data from the EdaMove 3 you have to read out the sensor after the measurement The results of movisensXS only contain the sensor information that causes a trigger...

Page 32: ...rge multiple sensors at the same time we suggest using a USB hub see 4 2 After connecting the sensor to a USB port the charging process starts immediately During charging the status LED is blinking bl...

Page 33: ...advise the test persons to recharge the sensor every day until it is blinking yellow The recommended duration for daily recharging is 15 minutes If you recharge the sensor regularly you can make a me...

Page 34: ...after a long period where it was not used it can take up to several minutes until the sensor reacts and can be identified by the computer You can check the battery status before the measurement with...

Page 35: ...described in chapter 6 2 Step 1 Start the SensorManager by selecting Windows Startmenu movisens SensorManager SensorManager SensorManager is now searching for available sensors Step 2 Connect EdaMove...

Page 36: ...imum measurement duration can only be reached when the battery is fully charged When connecting for the first time allow up to 30 seconds for the device to be detected as it installs the driver 7 3 St...

Page 37: ...ithout recharging the sensor see 0 Start time You can start the measurement immediately or delayed at a specific time If you want to start your measurement delayed please specify date and time The giv...

Page 38: ...the measurement the LED stops flashing If you reconnect the sensor after starting a measurement again with a PC the measurement will be stopped prematurely If you connect the sensor to a USB charger t...

Page 39: ...m in the hand of the test person As the test person holds the electrodes in place secure the wrist strap over the cables The strap should be firm but not too tight This helps to keep the cables secure...

Page 40: ...ity parameters like Movement Acceleration and activity class can be reliably detected and used for calculation The following figure and table lists the possible sensor locations supported by the DataA...

Page 41: ...position Energy expenditure right left wrist right left ankle 7 5 Stopping a Measurement The measurement will automatically be stopped if the configured measurement duration has passed A running measu...

Page 42: ...sensor nor in the SensorManager software That allows you to have a sustainable database with all the raw data of your study that can be used with future studies and with future algorithms To store re...

Page 43: ...37 7 Step 3 Click on Save Data You will see the following window...

Page 44: ...th the movisens DataAnalyzer the additional information about the person and the sensor location is mandatory Step 5 Finally click on Save data The measurement data will be stored either in the unisen...

Page 45: ...eleration bin is the result of the live analysis on the sensor the other bin files are the raw data of the other measurement parameters If you select to store data in csv format the following files wi...

Page 46: ...of data storing process The following window is shown Tip When storing data as csv file you have to take into account that the size of the data file doesn t exceed the maximum size of the program you...

Page 47: ...ed measurements click on Show data directly after storing the data To view previously stored measurements use Windows Explorer to navigate to your measurements folder and then open the folder with the...

Page 48: ...to the desired time set markers and annotate artefacts Details can be found in the online help of UnisensViewer You directly start the analysis of the data with DataAnalyzer by clicking the Analyze Da...

Page 49: ...43 7...

Page 50: ...aw data acquired from sensors that also record raw data in the unisens format DataAnalyzer calculates secondary parameters from your physiologic measurement data creating summaries and reports in just...

Page 51: ...set A unisens data set consists of a meta file unisens xml and additional data files for each measurement signal and secondary parameter Secondary parameters are stored as a csv file within the unise...

Page 52: ......

Page 53: ...2 Cleaning Instructions If you want to clean EdaMove 3 please note the following Disconnect the sensor from USB cable and wrist band Use a soft slightly moistened cloth Take care that no humidity ente...

Page 54: ...ipment Please consider your local regulations for waste disposal 8 6 Troubleshooting You can find answers to the most common questions here https www movisens com en faq Error Solutions Sensor is not...

Page 55: ...49 8 when it is reset Flashing Red 3 times per second An error occurred Reset sensor If the sensor doesn t stop flashing please contact the manufacturer...

Page 56: ...echarging time 1 hour Size of sensor W x H x D 62 3mm x 38 6mm x 11 5mm Weight of sensor 31 g Internal sensors EDA sensor Exosomatic method constant voltage DC 0 5V Resolution 14 bit Input range 2 S u...

Page 57: ...ED 3 color Vibration alarm Marker Interfaces Micro USB Bluetooth Smart 4 0 API Java API for USB Windows Example for Bluetooth Smart Android Wear locations Wrist Ankle Environmental conditions Temperat...

Page 58: ......

Page 59: ...ns makes no representations or warranties with respect to this manual or with respect to the products described herein movisens shall not be liable for any damages losses costs or expenses direct indi...

Page 60: ...Bedienungsaneitung movisens GmbH Augartenstra e 1 76137 Karlsruhe Germany Tel 49 721 381344 0 Fax 49 721 381344 90 support movisens com http www movisens com...

Reviews: