Electrical installation
•
The mixer needs a 3 phase power connection with a voltage of 400 Vac
(other voltages on special request)
•
The mixer will be delivered with a combined Main switch / thermal motor safety switch and cable
between the motor reducer and main switch.
•
The mains power connection has to be made by the customer.
•
Connect the earth wire to point where the green/yellow (earth) wire is connected.
•
The 3 phases must be connected to the connections 1L1, 3L2 and 5L3.
•
The motor rotation direction must be anti-clockwise.
This can be seen at the hexagonal bolt on the end of the mixer axis.
•
If the axis is turning clockwise after switch ON the mixer, 2 phases must be exchanged.