MC-Balance manual
23
How to make a material calibration?
•
Go to the CALIBRATION menu.
•
Enter Material name and your production parameters.
•
Start calibrating. The following screen appears:
•
The calibration will take minimal about 3 minutes but can take more time depending on the
used material and production parameters.
It is possible to stop during the calibration (for example to refill the hopper).
To continue select YES and confirm. To stop select NO and confirm.
•
The calibration will automatically be finished and saved after the Setpoint is reached within the
set calibration deviation (Cal dev: default = 5%) set in configurations menu. (see chapter 7.4)
•
After saving you will automatically go to the PRODUCTION menu and stored calibration is
automatically selected.
Stored material curves have a
*
after the filename.
During the calibration the unit is regulating to his Setpoint. When this point is reached the
calibration will be saved automatically. On the basis of this point a complete curve is made on
bases of default pre-programmed curves.
Material Calibration
It is also possible to save the actual material calibration during a running production process.
This function is called the “
Save data Function”,
for more information see chapter 7.8
How can I select a calibrated material?
When one or more material calibrations are made, one of these can be selected as follows:
•
Go to PRODUCTION <menu>
•
Use the cursor to go to Material.
•
Press 2 seconds on the <enter> button
A list will appear with stored material calibrations
•
Select one with arrow buttons and confirm
If the material calibration made is not in the list fill in the first letter(s) and confirm. Now a filtered list
appears. To go back to the main list fill in spaces and confirm.
It is also possible to fill in the material description immediately in the PRODUCTION <menu> and
confirm. The message
“Material not found, select new material”
appears when a false material
is filled in. To clear the material description fill in spaces or select an empty material calibration out
of the list.
How can I delete or rename a calibrated material?
To delete one or more material see chapter 7.13.
To delete all Materials select master reset MATERIAL in the CONFIGURATIONS <menu> and
confirm.
CALIBRATION
[TESTING BUSY]
[*****]
Set : 1,000 gr/s
Actual : 0,945 gr/s
Stop & Store : YES/NO
Single point calibration on basis of pre-
programmed MOVA-curve
Summary of Contents for MC-BALANCE
Page 1: ...MC Balance User Manual 4 0 UK 00 Software version V4 0 Manual revision 0 0 Date April 2008 ...
Page 2: ......
Page 47: ...MC Balance manual 44 General dimension MC Balance ME25G NST40 Neckpiece ...
Page 48: ...MC Balance manual 45 General dimension MC Balance MV25G NST40 Neckpiece ...
Page 49: ...MC Balance manual 46 General dimension MC Balance Support frame NST40 Neckpiece ...