12
6.5 Electrical Connections
The MC-12 needs an input signal from the production machine in order to operate.
Two different input signals can be used to control the MC-12.
1.
A potential free relay contact
.
Use the white and brown wire for the potential free contact.
2.
A relay signal up to 24 Volt DC
.
Relay signals can be used for an extruder that has not a tacho signal. In case of a powered
relay signal connect the white wire to +24 VDC and the yellow wire to - side.
See
APPENDIX A
for the wiring diagram.