MTWD (Digital Wrench) Operating Instructions
Rev 1.0 (3/29/2012)
Corporate Headquarters:
1080 North 11th Street, San Jose, CA 95112 Phone: (408) 292-2214 Fax: (408) 292-2733
www.mountztorque.com
Page 5
Light & Buzzer (Beep Tone) Alert
The tolerance setting provides a visual and sound signal if the
torque Passed or Failed. When applied torque reaches the pre-set
torque value, the GREEN & RED lights are on and the buzzer
beeps continuously. The LCD display shows the maximum applied
torque for 15 seconds then indicates "0".
When applied torque exceeds the wrench full-scale capacity, the
GREEN & RED lights are on and the buzzer beeps continuously.
Display shows “ ----“
Example
Condition: Torque value is set to 45 N.m, and the tolerance is set
to -10%
An alert tone will occur at 40.5 N.m. There will be a rapid pulsing
tone to indicate the torque value is closing to the target value (45
N.m).