Operation
Changing to the Normal Mode:
Press the F1 button for more than 2 seconds in the setting mode. Then the mode will be
changed to the normal mode and the value set for the count will be displayed.
Counter ON/OFF Setting:
Pressing of the F3 button toggles between ON and OFF. (Note: F2 button is not to be used.)
Value Setting for Each Function:
1. Pressing the F2 button in the setting mode changes the figure position for setting.
2 . Pressing the F3 button increases the value one by one.
Note : The setting procedure is the same for all the settings except for the Counter ON/OFF Setting. Refer to “
List of
Function Settings
” on page 5 for the setting range.
BLG-BC1 Series Operating Instructions
Corporate Headquarters:
1080 North 11th Street, San Jose, CA 95112 Phone: (408) 292-2214 Fax: (408) 292-2733
www.mountztorque.com
Page 8
Press it for more than 2 seconds.
(Counter Setting)
(Counter Setting)
(The selected figure position flashes)