background image

BLG-BC1 Series Operating Instructions

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.mountztorque.com

Name of Parts

BLG-4000BC1 (Lever Start type)

BLG-5000BC1 (Lever or Push Start) Selectable by the
Switch

Power tool cable

Knurled ground ring

Hanger

Joint ring

FOR/REV switch
FOR: Forward
OFF: Neutral
REV: Reverse

Bit

Switch lever

Torque adjust-
ment scale

Joint shaft collar

Torque adjust-

ment nut

Protective cover

for the torque

adjustment nut

(can be removed

by turning it CCW)

Two-way Start System (Switchable between 
Lever Start and Push-to-Start) 

Marking between “Lever” and 
“Push” start selection.
L

P

To change setings, 
see page 3

Power tool cable

Hanger

FOR/REV switch
FOR: Forward
OFF: Neutral
REV: Reverse

Driver
connector

Switch lever

Torque 

adjustment scale

Bit

Joint shaft collar

Transformer Guide

Model

Item #

For Use with Electric Screwdriver Models

T-30BL

144300

BLG4000BC1

T-70BL

144400

BLG4000BC1 - BLG5000BC1-HT

T-70BL

T-30BL

Page 2

Summary of Contents for BLG-4000BC1

Page 1: ...BLG BC1 Series Operating Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com Rev 1 1 4 25 17...

Page 2: ...st ment scale Joint shaft collar Torque adjust ment nut Protective cover for the torque adjustment nut can be removed by turning it CCW Two way Start System Switchable between Lever Start and Push to...

Page 3: ...the transformer Make sure notch at the cable end aligns with the notch on the driver connector Tighten knurled ground ring 2 Plug in power cord to the back of the transformer and power outlet Flip po...

Page 4: ...and the mode is changed to the normal mode F2 F3 Buttons Using these buttons the set value can be changed in the function settings Some set values are limited depending on the function that is being s...

Page 5: ...ted the counter function is available When selected it is used as a normal driver 2 Count The screw fastening count value is set Setting Range 1 to 99 3 Count Timer This function is used to prevent th...

Page 6: ...r Disable Reverse Count Disable Units Digit 2 Torque Up Buzzer Disable 3 Torque Up Buzzer Enable 7 Over Time Short Time This sets whether or not the Over Time Short Time error is detected 0 When selec...

Page 7: ...ode which provides you access to change any settings from Function List Refer to List of Function Settings on page 5 for the changing and setting any functions with the power tool BLG BC1 Series Opera...

Page 8: ...2 button in the setting mode changes the figure position for setting 2 Pressing the F3 button increases the value one by one Note The setting procedure is the same for all the settings except for the...

Page 9: ...the charts to determine the reference number setting for your torque requirement How to Read the Torque Charts Torque ranges lbf in approximate tightening torque operated with no load at maximum spee...

Page 10: ...s Do not place in operation where such objects as hair strings clothing etc can become tangled in the rotating bit 4 Keep away from moisture Never use in high humid moist or damp environment Mountz Ca...

Reviews: