background image

Zx020_02e_oi_e.doc / Apr-16 

 

Page 11 / 11 

7.

 

Dimensions 

 

7.1.

 

Mounting without use of add-on frames 

 
 
 
 
 
 
 
 
 
 

7.2.

 

Bezel 50 x 25 mm (1.969 x 0.984’’) for clip mounting 

 
 
 
 
 
 
 
 
 

7.3.

 

Bezel 50 x 25 mm (1.969 x 0.984’’) for screw mounting 

 
 

max. 19.3

4,0 (0.157’’)

6,5 (0.256’’)

59,0 (2.323’’)

22

x4

5

48,0  (1.890’’)

24

,0

  (

.9

45

’’)

22

,2

 (+

0,

3)

45,0 (+0,6)

1.772’’ (+ 0.024 )

0.

87

4’

’ (

+

0.

01

2)

max. 0.7 6’’

25

,0

 x 

50

,0

53,0  (2.087’’)

26

,0

  (

1.

02

4’

’)

1,0  (0 .039’’)

4,0  (0 .157’’)

25

,0

  +

0,

5

50,0  +0,6

(0

.9

84

 x 

1.

96

9

’’)

(1.969  +0.024’’)

0.

98

 +

0.

02

0

’’

56,0 (2.205’’)

32

,0

  (

1.

26

0’

’)

M3

40

,0

  (

1.

57

5’

’)

32

,0

  +

 0

,1

25

,0

 x

 5

0,

0

1,0  (0.039’’)

4,0  (0.157’’)

(0

.9

84

 x 

1.

96

9’

’)

25

,0

  +

0,

5

0.

98

 +

0.

02

0’

50,0  +0,6

(1.969  +0.0 24’’)

(1

.2

60

  +

0

.0

04

)

M3

A= Senkung       Af3, DIN 74
      Counterbore Af3, DIN 74

A

A

Summary of Contents for ZX020

Page 1: ...Product Features Miniature panel housing Bright LED display with 6 digits Add on frame for clip or screw mounting Counting frequency 15 to 60 kHz depends on counting mode Selectable filter for use wi...

Page 2: ...in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety I...

Page 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Page 4: ...sections for wiring are described in the Technical Specifications see chapter 6 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw term...

Page 5: ...ed and additionally press the right one After releasing the keys the display alternates between the parameter title and the setting of the parameter After pressing any key only the parameter value for...

Page 6: ...echnical Specifications chapter 6 on Filter on Maximum counting frequency 30 Hz 3 3 Input Mode of count impulses Input Cnt dir Input A Count input Input B Direction select up down Up dn Differential I...

Page 7: ...by the divider set 99 9999 Setting range 0 0001 to 99 9999 Setting 0 will not be accepted 3 5 Decimal point dP 0 Sets the decimal point of the display 0 000 Max 3 decimal places 3 6 Set Reset mode re...

Page 8: ...99999 Upon a Set Reset command the counter sets to the value entered here 99 9999 Range 199 999 999 999 3 8 End of program Endpro No Select No to return to the beginning of the menu for verification o...

Page 9: ...Page 9 11 4 Terminal Assignments also printed to the top of the unit 5 Delivery includes Panel mounting clip Bezel for screw mounting with panel cut out 50 x 25 mm Bezel for clip mounting with panel c...

Page 10: ...git height Range 6 digit LED red 8 mm 0 3149 inch 199999 999999 Housing Material Mounting Dimensions Miscellaneous Protection class Weight plastic panel cut out w x h 45 x 22 mm resp 1 772 x 0 866 inc...

Page 11: ...0 157 6 5 0 256 59 0 2 323 22 x45 48 0 1 890 24 0 945 22 2 0 3 45 0 0 6 1 772 0 024 0 874 0 012 max 0 76 25 0 x 50 0 53 0 2 087 26 0 1 024 1 0 0 039 4 0 0 157 25 0 0 5 50 0 0 6 0 984 x 1 969 1 969 0...

Reviews: