ZU25102A_e.DOC / Mrz-08
Page 16 / 26
9.
Parameter Settings
Parameter
Description
Display Setting:
x Operand
/ Operand
+/- Operand
These operands allow to convert the result to the desired engineering units.
The conversion affects the numeric value for serial read out from register
<:8> only, but not the scaling of the analogue output.
With settings x operand = 1.0000
/ operand = 1.0000
+/-
operand
=
0.0000
the readout from register < :8 > equals to the percentage result (xxx.xxx%) ,
where 100,000% has been defined by the TEACH minimum and TEACH
maximum settings
+/-Operand
Readout from <:8>
=
Measuring result in % of full scale
x
xOperand
/Operand
+
General Setting
Teach Minimum
Teach Maximum
This couple of settings define your minimum and maximum count for input
A and input B (if applicable), where your analogue output moves from 0 V
to 10 V.
You can enter your minimum and maximum settings as follows:
•
either by operating the Teach pushbutton
(like described already under 5.1)
•
or by entering the counter settings directly by keyboard to the
parameter field of your screen, without using the TEACH function.
When using summary or differential counting modes (A+B, A-B), these
settings already refer to the sum or the difference of the counter.