Pb340_01d_oi_e.doc / Apr-16
Page 13 / 15
Max_Module = 1
; Modular station with one module
Max_Input_len = 4
; 32 bit input data (PB306/541)
Max_Output_len = 4
; 32 bit output data (PB340/541)
Max_Data_len = 8
; Max. 2 * 32 bit data (PB541)
;
; UserPrmData:
;
Max_User_Prm_Data_Len = 1
; 1 byte user parameter data
;
; Module Definition List:
;
Module="PB340" 0xA3
; Config. PB340: 4 byte output data
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
Ext_User_Prm_Data_Ref(0) = 1
EndModule
;
Module="PB306" 0x93
; Config. PB306: 4 byte input data
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
EndModule
;
Module="PB541" 0xB3
; Config. PB541: 4 byte input data +
Ext_Module_Prm_Data_Len = 1
; 4 byte output data
Ext_User_Prm_Data_Const(0) = 0x00
Ext_User_Prm_Data_Ref(0) = 1
EndModule