6.
PC setup using the operator software OS32
You can apply the full set of functions when using a PC and our operator software OS32 for
setup of the unit. You can download this software and full instructions, free of charge, from our
homepage
www.motrona.de
•
Connect your PC to the converter, using a serial RS232 cable like shown in section 2.4 of
this manual. Make sure, the cable only connects pins 2, 3 and 5.
•
Run the OS3.x software and you will find the following screen:
•
In case your text and color fields remain empty and the headline says „OFFLINE“, you must
verify your serial settings. To do this, select „Comms“ from the menu bar. Ex factory, all
motrona
units use the following serial standard settings:
Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit
•
If the serial settings of the unit should be unknown, you can run the „SCAN“ function from
the „TOOLS“ menu to find out.