Fs340_02b_oi_e.docx / Nov-21
Page 38 / 49
Error Messages
Upon detection of an error, the carriage remains in a closed-loop standstill at home position
after termination of the current cut. Output “Error” switches to high and the unit displays a
flashing error message “Error…” indicating the error number.
To clear an error state either set “Clear Error” command or cycle the power supply
of the unit.
Please note that the unit will immediately return to the error state if the cause for the error has
not been eliminated.
Error No.
Error Description
Error 0
The reason for the error has been rectified (e. g. power supply voltage recovered
above minimum level) but the error has not yet been cleared by input “Clear
Error”.
Error 1
Cut not possible:
A cut is declared as “not possible” when the carriage already should start into
forward direction before it has fully returned to Home position from the previous
cut. This, in general, will happen with too short cutting lengths at too high line
speed.
Error 2
Limit Switch:
This error indicates that during automatic cutting operation the rear software
limit switch has been touched (See drawing at
parameter “Minimum Position”)
Error 3
Power Low:
The power supply voltage is too low.
This error is reset automatically when the power supply voltage recovers and
exceeds the minimum power supply voltage level.
Error 4
Val. Range exceed:
The ratio between the number of line encoder pulses and the number of carriage
encoder pulses is outside the permitted range (see chapter
Configuration)