Fan (VMX-AGY-030)
VMX-AGY-030 is designed for models VMX-AGY-101 to VMX-AGY-113. It increases the number of start/stop cycles
per hour. The fan operates automatically during a soft start or soft stop and will continue to run if the heatsink
temperature is > 113
o
F (45
o
C). The fan stops when the heatsink temperature has fallen below 104
o
F (40
o
C).
Installation
California Customers:
California Proposition 65 Warning
WARNING: this product and associated accessories may contain chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm. For more information visit
Step 1. Remove screw (x1) and retain
Step 2. Remove blanking plug (x1)
Step 3. Fit fan as shown
Step 4. Replace screw (x1)
Step 5. Fit flying lead from fan into
socket.