Outputs:
Starter Coil Interlock = Two sets of FORM “C” relay contacts for us
in interlocking the starter coil and/or other devices to prevent
energizing as the braking power is applied.
Mechanical brake Release = N.O. relay contact for use in controlling
electro-mechanical brake as a holding brake. When the ABC Series
is “disabled”, this circuit controls the mechanical brake normally as if
it is the only brake in the system.
Aux. Contact Ratings:
5 Amps, 250 VAC max.
LED Status Indicators:
Large LEDs: braking = green; Fault = Red
Small LEDs: Power On, Jog/Armed, Brake Off, Disabled, Over
Temp and Wiring Error.
Operating Design Temperature:
32ºF – 122ºF / 0ºC to 50ºC
Storage Temperature:
-4ºF – 176ºF / -20ºC to 80ºC
Ambient Conditions:
5% to 95% relative humidity
0 – 3300ft (1000m) elevation
Approval:
UL, cUL Listed
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]