Problem
Possible cause
Solution
Traverse range of the
fuel ring corresponds to
the size of one opening
in the fuel ring. How-
ever, the location of the
movement is wrong.
Incorrect adjustment of the
fuel ring.
See
Adjust Fuel Ring
Traverse range of the
fuel ring is too
small/too big.
A wrong VariFuel2/2+ is
configured in the stepper
motor driver.
Configure your VariStep3 stepper
motor driver via the MICT. Afterwards
if necessary adjust the fuel ring (see
Adjust Fuel Ring
Fuel ring scale is not in
the inspection window.
Home position lost.
See
Adjust Fuel Ring
POWER-LED of the
stepper motor driver
does not light up al-
though it is connected
to the supply voltage.
Stepper motor driver is
defective.
Replace the stepper motor driver.
Stepper motor does not
move without interrup-
tions.
There is
no
malfunction. When the air/fuel ratio is correct, the
motor remains in its position.
Summary of Contents for VARIFUEL2
Page 1: ...VariFuel2 2 Air Gas Mixer Assembly Instructions P N 01 10 001 EN Rev 09 2020...
Page 20: ...4 Product Description 20 Rev 09 2020 Dimensions Series 100 60 VariFuel2 VariFuel2...
Page 21: ...4 Product Description Rev 09 2020 21 Series 140 80 VariFuel2 VariFuel2...
Page 22: ...4 Product Description 22 Rev 09 2020 Series 200 120 VariFuel2 VariFuel2...
Page 23: ...4 Product Description Rev 09 2020 23 Series 250 150 VariFuel2 VariFuel2...
Page 24: ...4 Product Description 24 Rev 09 2020 Series 300 190 VariFuel2 VariFuel2...
Page 25: ...4 Product Description Rev 09 2020 25 Series 350 225 VariFuel2 VariFuel2 for eye bolt DIN 580...
Page 49: ...Rev 09 2020 49...
Page 50: ......