5 Functions
46
Rev. 06/2021
5.1.11
NO
ₓ
Monitoring Report
For each calendar year for which the NO
X
monitor has values, the EasyNO
ₓ
can generate a NO
X
monitoring report as a PDF file if needed and export it to a USB flash drive (see section
Export
on
X
monitoring report contains the following information:
Pos.
Description
Name of the monitored engine
Operator information
Annual summary
Time limit for twelve consecutive months as per 44th BImSchV § 20 (4)
Configuration of the respective NO
X
monitor
Logbook of the respective NO
X
monitor
Daily values of the respective NO
X
monitor
Miscellaneous data on the EasyNO
ₓ
Exceedances of the time limit within twelve consecutive months are highlighted in red in the
Sum
column of the time limit overview
.
Summary of Contents for EasyNOx
Page 1: ...EasyNOX NOX Monitoring Operating Manual P N 01 50 026 EN Rev 06 2021 ...
Page 33: ...4 Product Description Rev 06 2021 33 4 1 7 Overview Drawings 4 1 7 1 Dimensions EasyNOX ...
Page 34: ...4 Product Description 34 Rev 06 2021 ...
Page 35: ...4 Product Description Rev 06 2021 35 CAN Bus NOX Sensor Module P N 63 05 015 ...
Page 36: ...4 Product Description 36 Rev 06 2021 I O Communication Module Optional ...