V.3229 / V.3229L
<C#>-11
7
V.25 bis Autodialer
Responses:
Same as for the CRS command.
Failure response is
{sep}
r;
{call progress messages}...
where
r
is the recall count (1 < =
r
< =
n;
1,2...,etc.),
followed by a separator field
<etb><sy><sy><stx>
and call progress messages (CFI XX, etc.). If the call
fails to connect, this is repeated for the specified
number of times.
Link Number by
Address
PRL
a;b
This command links the number at address
a
with the
number at address
b
. The addresses are one digit
decimal values. Linking numbers enables different
numbers to be dialed if a call failure occurs.
Only forward linking to one other number is allowed,
so address 1 can be linked to 4 to 8 to 9 etc.; however
(using this example), if address 4 is dialed by a CRS
command without connection it links forward to 8
then to 9.
If all these fail to connect, the autodialer will not
back-link to address 1 unless circular linking is used.
Numbers may be linked as 4 to 5 to 3; however, if
address 3 is dialed, back-linking to 5 is not allowed.
If circular linking (1 to 8 to 7 to 1) is used, dialing is
discontinued after the addressed number in the dial
command has been dialed twice. If only one param-
eter follows the PRL command, the number at ad-
dress a is unlinked from its forward link.
Summary of Contents for V3229 - 14.4 Kbps Modem
Page 14: ... C Introduction V 3229 V 3229L C 7 Reference Installation ...
Page 17: ... C Introduction C 10 V 3229 V 3229L Reference Installation ...
Page 18: ... C Introduction V 3229 V 3229L C 11 Reference Installation ...
Page 37: ...V 3229 V 3229L C 19 3 Option Selection ...
Page 53: ... C 16 V 3229 V 3229L Reference Operation SECURE 14400 xxx ...
Page 61: ... C 24 V 3229 V 3229L Reference Operation ...
Page 62: ...V 3229 V 3229L C 25 Reference Operation V 32 Cleardown ...
Page 64: ...V 3229 V 3229L C 27 Reference Operation ...
Page 126: ... C 62 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Page 135: ...V 3229 V 3229L C 71 5 Asynchronous Operating Commands ...
Page 136: ... C 72 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Page 149: ...V 3229 V 3229L C 13 6 Status Registers value is 0 S19 20 ...
Page 156: ... C 20 V 3229 V 3229L 6 Status Registers default ...
Page 159: ...V 3229 V 3229L C 23 6 Status Registers S40 50 ...
Page 171: ...V 3229 V 3229L C 35 6 Status Registers default ...
Page 214: ... C 2 V 3229 V 3229L 9 Maintenance ...
Page 221: ...V 3229 V 3229L C C Reference Interfaces ...
Page 222: ... C D V 3229 V 3229L Reference Phone Jack Descriptions ...