STARLINE 3
Table 1 identifies and provides information on the user-interface features of the SG4-DRT-2X:
Key Feature
Description
1
0.5 V/mW
This test point enables monitoring of the optical output level of the module.
The nominal scale factor is 0.5 V/mW. Note that the optical power test point
does not track changes in optical power due to the laser tracking error.
2
ENABLE/FAULT
A red LED (
FAULT
) indicates that the laser output power is below normal
limits. Because the laser output requires a short period of time to stabilize, it
is normal for the LED not to illuminate for approximately 10 seconds. Note
that the module must be enabled for the fault indicator to function.
A green LED (
ENABLE
) provides visual indication of the transmitter’s enable
status.
3
CH A
RF input test point (
−
5 dBmV nominal total power)
4
CH A
JXP attenuator location. Used to adjust
−
5 dBmV nominal total power
reading at
CH A
test point.
5
This MCX connector provides the SG4-DRT-2X with
CH A
RF input through a
cable connection from the configuration board in an SG4000.
6
Optical bulkhead with SC/APC type connector that provides output from the
SG4-DRT-2X
7
This MCX connector provides the SG4-DRT-2X with
CH B
RF input through a
cable connection from the configuration board in an SG4000.
8
CH B
JXP attenuator location. Used to adjust
−
5 dBmV nominal total power
reading at
CH B
test point.
9
CH B
RF input test point (
−
5 dBmV nominal total power)
SG4-DRT-2X Installation Sheet