Summary of Contents for RFS4011 Series

Page 1: ...RFS4011 Series Integrated Services Controller Installation Guide M RFS4000_Baseline book Page 1 Tuesday September 28 2010 9 55 AM ...

Page 2: ...tent Trademark Office Symbol is a registered trademark of Symbol Technologies Inc All other product or service names are the property of their respective owners Motorola Inc 2010 All rights reserved RFS4000_Baseline book Page 2 Tuesday September 28 2010 9 55 AM ...

Page 3: ... Hardware Setup 13 5 0 Quick Start Information 25 6 0 Regulatory Information 27 7 0 Part Numbers Support and Sales 35 8 0 End User License Agreement 36 9 0 RFS4011 China ROHS Compliance 39 Contents RFS4000_Baseline book Page 3 Tuesday September 28 2010 9 55 AM ...

Page 4: ...RFS4000_Baseline book Page 4 Tuesday September 28 2010 9 55 AM ...

Page 5: ...management reducing wireless networking complexity by moving management out of the ceiling and into the wiring closet The RFS4011 can adopt up to 36 Adaptive APs or 6 Thin Access Points The RFS4011 has integrated dual 802 11n radios that are band unlocked to provide access in both 2 4GHz and 5GHz simultaneously or provide access in either band with the second radio capable of doing 24 by 7 securit...

Page 6: ...wer circuits during thunderstorms or other weather conditions that could cause a power surge Verify there is adequate ventilation around the device and ambient temperatures meet equipment operation specifications This product is designed for in building installation only and is not intended to be connected to exposed outside plant networks 1 4 Site Preparation Consult your site survey and network ...

Page 7: ...tion Be sure to use a surge protection device between the electricity source and the RFS4011 Series Integrated Services Controller Install an Uninterruptible Power Supply UPS A UPS provides continuous power during a power outage Some UPS devices have integral surge protection UPS equipment requires periodic maintenance to ensure reliability A UPS of the proper capacity for the data processing equi...

Page 8: ...hernet Ports have two status LEDs These LEDs display two colors green amber and three lit states solid blinking and off Five of the Gigabit Ethernet Ports also support Power over Ethernet PoE and have corresponding PoE LEDs The following tables decode the combinations of LED colors and states for the System Status Radio and the Gigabit Ethernet and PoE LEDs 3 1 System Status LEDs SYS 1 2 System St...

Page 9: ...en Solid Off POST succeeded Normal Operation Amber Blinking Off POST Failure Alternating Green Blinking Amber Blinking Alternating Green Blinking Amber Blinking System Boot Up Error NOTE During controller start up the Temperature status LED will be lit Solid Amber This is norma behavior and does not indicate an error At the completion of start up the Temperature Status LED will switch to Solid Gre...

Page 10: ...mary System Normal Operation Actively Adopting Access Ports Green Solid Amber Blinking No Country Code configured on the controller or Access Port or Adaptive AP License and Country Code configured but no APs adopted System Status 1 LED System Status 2 LED Event Off Off Power off Green Solid Off Redundant System Normal Operation Green Blinking Green Solid Redundant System failed over and adopting ...

Page 11: ...ed Temperature LED Event Off System Off Green Solid Ambient Inlet Temperature is within specified operating limit Amber Solid Ambient Inlet Temperature is near the maximum operating temperature During controller start up this LED will be lit Solid Amber This is normal behavior and does not indicate an error Amber Blinking Ambient Inlet Temperature is above the maximum specified operating temperatu...

Page 12: ...lled Green Solid Radio Present but not configured 2 4GHz Band Green Blinking Activity Transmit Recieve 2 4GHz Band Radio 1 LED 2 Event Off WLAN Radio Disabled or Not Installed Green Solid Sensor Mode without Sensor Server connected Green Blinking Sensor Mode with Sensor Server connected RADIO 1 RADIO 2 RFS4000_Baseline book Page 8 Tuesday September 28 2010 9 55 AM ...

Page 13: ...but not configured 5 2GHz Band Amber Blinking Activity Transmit Recieve 5 2GHz Band Radio 2 LED 2 Event Off WLAN Radio Disabled or Not Installed Green Solid Sensor Mode without Sensor Server connected Green Blinking Sensor Mode with Sensor Server connected RFS4000_Baseline book Page 9 Tuesday September 28 2010 9 55 AM ...

Page 14: ...ries Integrated Services Controller Installation Guide 10 3 3 RJ 45 Gigabit Ethernet LEDs 5 4 3 2 1 LAN PoE Port speed Port activity PoE Status LED RFS4000_Baseline book Page 10 Tuesday September 28 2010 9 55 AM ...

Page 15: ... Port Fault Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity Transmit and Receive Amber Blinking Link Fault PoE Status LED Event Off PoE Disabled or Not in Use Green Solid PoE Enabled and Powering Port Amber Solid PoE Over Limit Amber Blinking PoE Port Fault RFS4000_Baseline book Page 11 Tuesday September 28 2010 9 55 AM ...

Page 16: ...tivity LED Port Speed LED Event Green Blinking 1000 Mbps Amber Blinking Module or Tx Rx Fault Loss Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Operational Amber Blinking Module or Tx Rx Fault Loss UPLINK SFP Port speed Port activity RFS4000_Baseline book Page 12 Tuesday September 28 2010 9 55 AM ...

Page 17: ...Hardware Setup 13 4 Hardware Setup Console PoE enabled gigabit ethernet USB UPLINK ExpressCard RADIO 1 RADIO 2 RFS4000_Baseline book Page 13 Tuesday September 28 2010 9 55 AM ...

Page 18: ...for each port For software configuration please see the RFS Series Integrated Services Controller Wi NG System Reference Guide available from the Motorola website 4 2 Gigabit Ethernet on the RFS4011 The RFS4011 has five RJ 45 Gigabit Ethernet LAN ports and one 1 combo Gigabit RJ45 SFP uplink port Using the RJ 45 ports requires connecting a Category 6 Ethernet cable to the port To use the Gigabit S...

Page 19: ...ng Gigabit Ethernet SFPs 1 Open the bail on the transceiver 2 Insert the SFP transceiver into the corresponding port on the controller Open bail to insert SFP transceiver RFS4000_Baseline book Page 15 Tuesday September 28 2010 9 55 AM ...

Page 20: ...er Installation Guide 16 3 Once the SFP transceivers are properly seated in their ports close the bails to lock the transceivers in place Close bail to lock SFP transceiver in place RFS4000_Baseline book Page 16 Tuesday September 28 2010 9 55 AM ...

Page 21: ...Hardware Setup 17 4 Insert the fiber optic cables into the installed transceivers RFS4000_Baseline book Page 17 Tuesday September 28 2010 9 55 AM ...

Page 22: ...ve to the USB 2 Wait a few seconds for the drive to be recognized by the controller 3 Follow the instructions in the RFS Series Integrated Services Controller Wi NG System Reference Guide or RFS Series Integrated Services Controller Wi NG CLI Reference Guide for more information on accessing USB storage devices from the controller for file transfers or firmware updates NOTE The controller supports...

Page 23: ...umber RFS 4011 MTKT2U WR To install the RFS4011 in a rack 1 Attach the controller to the 2U rack mount kit using the guides provided 2 Place the power supply unit in the rack mount tray in the space provided 3 Attach the mounting tray to the rack using screws appropriate for your rack s mounting holes 2U Rack Mount Kit Front Attach to Rack Power Supply RFS4000_Baseline book Page 19 Tuesday Septemb...

Page 24: ...ional antenna facade Motorola Part Number ML 2452 PTA4M3X3 1 To install the RFS4011 antenna facade 1 Align the antenna connectors on the antenna facade with the antenna connectors on the back of the RFS4011 2 Connect the numbered antenna connectors on the antenna facade to the corresponding connectors on the back of the RFS4011 RFS4000_Baseline book Page 20 Tuesday September 28 2010 9 55 AM ...

Page 25: ... securely connected align the two side and two rear clips on the antenna facade with the corresponding holes on the RFS4011 4 Gently press down on the antenna facade until the clips click into place RFS4000_Baseline book Page 21 Tuesday September 28 2010 9 55 AM ...

Page 26: ...ies Integrated Services Controller to the network and prepare it for initial configuration 1 Using the supplied console cable connect the RFS4011 serial port to an RS 232 DB 9 serial port on a separate computer the configuration computer CONSOLE Console Port RFS4000_Baseline book Page 22 Tuesday September 28 2010 9 55 AM ...

Page 27: ...Motorola Part Number 86 120786 01 into the power inlet at the back of the RFS4011 2 Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC Terminal Type VT 100 Port COM port Terminal Settings 19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression Power Inlet RFS4000_Baseline book Page 23 Tuesday September 28 2010 9 55 AM ...

Page 28: ... 1 LED will be lit solid green As the software is initialized the System 2 LED will blink green After the software has finished initializing the System 1 LED will be lit solid green and the bottom System 2 LED will be off The RFS4011 Series Integrated Services Controller is ready to be configured as described in the RFS Series Integrated Services Controller WiNG System Reference Guide Other LED co...

Page 29: ...nnect the other end to a computer with a working web browser 2 Set the computer to use an IP address between 192 168 0 10 and 192 168 0 250 on the connected port Set a subnet network mask of 255 255 255 0 3 Once the computer has an IP address point the web broswer to http 192 168 0 1 and the following login screen will display 4 Enter the default username admin in the Username field 5 Enter the de...

Page 30: ...he initial setup wizard 8 On the first screen of the wizard change the default Password and enter a Location and Contact name 9 Select a Time Zone and Country for the RFS4011 10 Select each of the access methods allowed to access the device 11 Click the Next button to continue to the next step and follow the onscreen instructions to complete the initial setup wizard RFS4000_Baseline book Page 26 T...

Page 31: ...lease refer to the Declaration of Conformity DoC for details of other country markings This is available at http www motorola com doc Note 1 For 2 4GHz Products Europe includes Austria Belgium Bulgaria Czech Republic Cyprus Denmark Estonia Finland France Germany Greece Hungary Iceland Ireland Italy Latvia Liechtenstein Lithuania Luxembourg Malta Netherlands Norway Poland Portugal Romania Slovak Re...

Page 32: ...rmation on International human exposure to eletromagnetic fields refer to the Motorola Symbol Declaration of Conformity DoC at http www motorola com doc EU Remote and Standalone Antenna Configurations To comply with EU RF exposure requirements antennas that are mounted externally at remote locations or operating near users at stand alone desktop of similar configurations must operate with a minimu...

Page 33: ...ns Wireless Devices Countries Country Selection Select only the country in which you are using the device Any other selection will make the operation of this device illegal Operation in the US and Canada The use on UNII Unlicensed National Information Infrastructure Band 1 5150 5250 MHz is restricted to indoor use only any other use will make the operation of this device illegal The available chan...

Page 34: ... the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Radio Frequency Interference Requirements Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Radio Transmitt...

Page 35: ...50 5 65GHz Brazil Declarações Regulamentares para RFS 4011 Brasil Nota A marca de certificação se aplica ao Transceptor modelo RFS 4011 Este equipamento opera em caráter secundário isto é não tem direito a proteção contra interferência prejudicial mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário Para maiores informações sobre ANATEL consulte o...

Page 36: ...Guide 32 Taiwan 在 5 25 5 35 秭赫頻帶內操作之無線資訊傳輸設備 限於室內使用 Korea 당해 무선설비는 운용 중 전파혼신 가능성이 있음 당해 무선설비 는전파혼 신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없습니다 Turkish WEEE Statement of Compliance EEE Yönetmeliğine Uygundur RFS4000_Baseline book Page 32 Tuesday September 28 2010 9 55 AM ...

Page 37: ...nden Sie unter http www symbol com environmental_compliance Eesti EL klientidele kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise eesmärgil Symbol ile Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun aadressi http www symbol com environmental_compliance Español Para clientes en la Unión Europea todos los productos deberán entregarse a Symbol al final de su ciclo ...

Page 38: ...e van hun levensduur naar Symbol te worden teruggezonden voor recycling Raadpleeg http www symbol com environmental_compliance voor meer informatie over het terugzenden van producten Português Para clientes da UE todos os produtos no fim de vida devem ser devolvidos à Symbol para reciclagem Para obter informações sobre como devolver o produto visite http www symbol com environmental_compliance Slo...

Page 39: ...mits set forth in support agreements If you purchased your Enterprise Mobility business product from a Motorola business partner contact that business partner for support Customer Support Web Sites Motorola s Support Central Web site located at http supportcentral motorola com provides information and online assistance including developer tools software downloads product manuals and online repair ...

Page 40: ...ource code or structure sequence and organization of the Software or iii rent lease or use the Software for timesharing or service bureau purposes or otherwise use the Software for any commercial purpose on behalf of any third party Licensee shall maintain and not remove or obscure any proprietary notices on the Software and shall reproduce such notices exactly on all permitted copies of the Softw...

Page 41: ...arranties or conditions of merchantability of fitness for a particular purpose of lack of viruses of accuracy or completeness of responses of results and of lack of negligence or lack of workmanlike effort all with regard to the Software and the provision of or failure to provide Support Services ALSO THERE IS NO WARRANTY OR CONDITION OF TITLE QUIET ENJOYMENT QUIET POSSESSION CORRESPONDENCE TO DES...

Page 42: ...ncy or authority and Licensee shall not export or allow the export or re export of the Software in violation of any such restrictions laws or regulations By downloading or using the Software Licensee agrees to the foregoing and represents and warrants that Licensee is not located in under the control of or a national or resident of any restricted country 13 MISCELLANEOUS Licensee may not sublicens...

Page 43: ...s table was created to comply with China RoHS requirements for Motorola s RFS4011 部件名称 Parts 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr6 多溴联 苯 PBB 多溴二苯 醚 PBDE 金属部件 Metal Parts O O O O O O 电路模块 Circuit Modules X O O O O O 电缆及电缆组件 Cables and Cable Assemblies O O O O O O 塑料和聚合物部件 Plastic and Polymeric Parts O O O O O O 光学和光学组件 Optics and Optical Components O O O O O O 电池 Batteries O O O O O O 15 RFS4000_Baselin...

Page 44: ...RFS4011 Series Integrated Services Controller Installation Guide 40 RFS4000_Baseline book Page 40 Tuesday September 28 2010 9 55 AM ...

Page 45: ...MOTOROLA INC 1303 E ALGONQUIN ROAD SCHAUMBURG IL 60196 http www motorola com 72 139899 01 Revision B September 2010 RFS4000_Baseline book Page 1 Tuesday September 28 2010 9 55 AM ...