603 Hardware Specifications
29
Appendix A
General Handling Recommendations for the
C4-CQFP Package
The following list provides a few guidelines for package handling:
•
Handle the electrostatic discharge sensitive (ESD) package with care before, during, and after
processing.
•
Do not apply any load to exceed 3 Kg after assembly.
•
Components should not be hot-dip tinned.
•
The package encapsulation is an acrylated urethane. Use adequate ventilation (local exhaust) for all
elevated temperature processes.
The package parameters are as follows:
Heat sink adhesive
AIEG-7655
IBM reference drawing
99F4869
Test socket
Yamaichi QFP-PO 0.5-240P
Signal
165
Power/ground
75
Total
240
A.1 Package Environmental, Operation, Shipment,
and Storage Requirements
The environmental, operation, shipment, and storage requirements are as follows:
•
Make sure that the package is suitable for continuous operation under business office environments.
— Operating environment: 10
°
C to 40
°
C, 8% to 80% relative humidity
— Storage environment: 1
°
C to 60
°
C, up to 80% relative humidity
— Shipping environment: 40
°
C to 60
°
C, 5% to 100% relative humidity
•
This component is qualified to meet JEDEC moisture Class 2.
After expiration of shelf life, packages may be baked at 120
°
C (+10/–5
°
C) for 4 hours minimum
and then be used or repackaged. Shelf life is as specified by JEDEC for moisture Class 2
components.
A.2 Card Assembly Recommendations
This section provides recommendations for card assembly process. Follow these guidelines for card
assembly.
•
This component is supported for aqueous, IR, convection reflow, and vapor phase card assembly
processes.
•
The temperature of packages should not exceed 220
°
C for longer than 5 minutes.
•
The package entering a cleaning cycle must not be exposed to temperature greater than that
occurring during solder reflow or hot air exposure.
•
It is not recommended to re-attach a package that is removed after card assembly.