background image

  Applicant:  Motorola, Inc.                                                     FCC ID: AZ489FT7006

Exhibit 8

Exhibit 8

 User Manual

 

User Manual MW 800 Display

 28 PDF pages total, 22 numbered pages

Please find the information required by Part 15.19, 15.21 & 15.105 on
page 4 of this PDF file.

Note:

 The Item above follow this cover page

Summary of Contents for MW800 Series

Page 1: ...FT7006 Exhibit 8 Exhibit 8 User Manual User Manual MW 800 Display 28 PDF pages total 22 numbered pages Please find the information required by Part 15 19 15 21 15 105 on page 4 of this PDF file Note The Item above follow this cover page ...

Page 2: ...a Owner s Manual MW 800 Display 68P02969C35 O DRAFTMarch 06 2003 68P02969C35 O 6802969C35 ...

Page 3: ......

Page 4: ...r party This is the complete warranty for the Product manufactured by Motorola Motorola assumes no obliga tions or liability for additions or modifications to this warranty unless made in writing and signed by an officer of Motor ola Unless made in a separate written agreement between Motorola and the original end user purchaser Motorola does not warrant the installation maintenance or service of ...

Page 5: ... to any claim of patent infringement which is based upon the combination of the Product or its parts furnished hereunder with software apparatus or devices not furnished by Motorola nor will Motorola have any liability for the use of ancillary equipment or software not furnished by Motorola which is attached to or used in connection with the Product The foregoing states the entire liability of Mot...

Page 6: ...d the Motorola logo are registered trademarks of Motorola Inc Microsoft MS DOS MS Windows and Windows are registered trademarks of Microsoft Corporation Adobe and Acrobat are registered trademarks of Adobe Systems Incorporated ...

Page 7: ...MW 800 Display Owner s Manual ...

Page 8: ...l Warnings 4 Display Unit Overview 7 Display Features 7 Display Buttons 8 Display Indicators 9 Speakers 10 Touchscreen 10 Display Connections 11 Standard Display Cable Adaptor 12 MW 800 Display Installation 12 Operating the MW 800 Display 13 Powering On 13 Powering Off 13 Adjusting the LCD Display 14 Powering On in Extreme Temperature Conditions 14 XGA Display Option 14 SVGA Display Option 15 Oper...

Page 9: ... Vehicle Battery 16 XGA Display Option 16 SVGA Display Option 16 Screen Calibration 16 Maintenance 17 Cleaning the MW 800 Display 17 17 Cleaning the Display 17 Tips for Using the MW 800 Display 17 Appendix A Approved Accessories 20 INDEX 21 ...

Page 10: ...ns Notational Conventions Throughout this publication you will notice the use of warnings cautions and notes These notations are used to emphasize that safety hazards exist and care must be taken Do not proceed beyond WARNING or CAUTION until the indicated conditions are fully understood and met WARNING CAUTION Indicates a potentially hazardous situation which if not avoided COULD result in death ...

Page 11: ...y of the operator An operational procedure practice condition etc which it is essential to emphasize Note For Vehicles With an Air Bag Do not place a portable radio in the area over an air bag or in the air bag deployment area Air bags inflate with great force If a portable radio terminal is placed in the air bag deployment area and the air bag inflates the radio terminal may be propelled with gre...

Page 12: ...Using the Manual 5 ...

Page 13: ...6 MW 800 Display Owner s Manual ...

Page 14: ...or keyboard and general purpose Note that all full speed USB devices must be connected directly to the USB port on the workstation Brightness is manually adjustable sunlight visible at high level and night light dim at low level Smart thermal management in extreme high or low temperatures A backlight heater for low temperatures Bluetooth radio connection option Eight software controled function ke...

Page 15: ...ght Indicator Screen Brightness Indicator Volume Indicator Increase Screen Brightness Decrease Screen Brightness Emergency button Function Keys Left Speaker Right Speaker Bluetooth Antenna Button Description Workstation Power To turn the MW 800 Display Workstation on or off Suspend Resume To toggle the MW 800 Display between Suspend and Resume modes When in Suspend mode the display and computer se...

Page 16: ...er arrow to decrease the speaker s volume level You may tap up to 64 continuous linear volume levels User defined To carry out specific functions depending on specific user application Emergency To send an emergency message to the RF host computer The Emergency button will be functional as soon as you power the workstation This key functionality depends on the definition given by each user system ...

Page 17: ...ars on the screen The new volume setting is saved in the memory Touchscreen The resistive touchscreen is sealed against moisture and dirt and can be operated with gloved hands For detailed information on the Suspend Resume green On Off System is in Suspend mode Normal operation Backlight green On Blinking Off LCD backlight is off Ignore this information LCD backlight is on RGB green On Off Valid R...

Page 18: ...a single image on screen for an extended period of time Note Caution Display Power Display In USB Port 2 USB Port 1 Connector Description Display Power DC connector for vehicle Requires a standard Motorola power cable with 15 A fuse Display In RGB USB and Sound from workstation USB 1 USB 2 Ports USB 1 to Keyboard and USB 2 to any peripheral device Note that all full speed USB devices must be conne...

Page 19: ...hed to any display mount by Phillips screws supplied in the display shipping carton The display cable from the workstation is routed through the mount and connected to the lower back side of the display Use caution when assembling the cable to the display to prevent damage to the display or the cable All display options have an additional power cable that must be used to supply power to the displa...

Page 20: ...e front panel of the CPU box or press the Workstation Power button on the display Upon power up the display power and OSD indicators are lit indicating that the system is on and the display is properly connected to the CPU box Powering Off To turn the workstation press the CPU box Power button momentarily the workstation will shut down Remember to save important information before turning off the ...

Page 21: ...tness of the display is affected by the settings of the brightness control of the color palette Adjustment of the color palette in Windows XP can be made in the Control Panel under the Appearance tab of the Display section Best results are obtained using the OSD application scheme Powering On in Extreme Temperature Conditions XGA Display Option The MW 800 Display operating temperature range is 4 t...

Page 22: ... blink and the backlight heater will start operating When the CCFL Cold Cathode Fluorescent Lamps temperature reaches 32 F 0 C after approximately 2 minutes the MW 800 will automatically turn on If the ambient temperature is in the 30 to 68 F 0 C 20 C range the backlight heater will operate and the MW 800 Display will turn on at once The heater turns off when the CCFL temperature reaches 122 F 50 ...

Page 23: ...a Discharged Vehicle Battery XGA Display Option If during normal operation the vehicle battery voltage drops to 10 2V the power status LED will blink and a warning message will be displayed on the screen If the voltage continues to drop the MW 800 will automatically power off at 8 5V SVGA Display Option During power cranking the display backlight is automatically turned off at 8V to save power The...

Page 24: ... clean the LCD use a soft cloth with ethyl or rubbing isopropyl alcohol Wipe the screen lightly Turn your equipment off if you accidentally Expose the LCD to liquid Drop jar or damage the LCD Call a service technician if either of these instances occur Tips for Using the MW 800 Display This information will help you avoid potential problems when you use the MW 800 Display Follow all the instructio...

Page 25: ...s Expansion USB 2 internal and 2 external ports Display Keys 8 illuminated function keys Control Keys 8 control keys Radio Communications Bluetooth Radio Class 2 2 402 2 480 GHz ISM band Housing Display Size 12 1 x 12 x 2 26 7 x 30 5 x 5 1 cm Environmental Operating Temperature 20 to 50 C Storage Temperature 40 to 70 C Humidity 90 to 95 non condensing 50 C Vibration Per MIL STD 810E Specifications...

Page 26: ...Tips for Using the MW 800 Display 19 ...

Page 27: ...ies Table 1 MW 800 Display Approved Accessories Accessory Part No Remarks DISPLAY CPU Cable 4 5FT 1 5M FKN8068 DISPLAY CPU Cable 9 6FT 3 2M FKN8069 DISPLAY CPU Cable 17FT 5 6M FKN8070 Display DC Cable FKN4711 DISPLAY Y CABLE FKN8090 Standard display cable adapter ...

Page 28: ...y 8 E Emergency button 9 extreme temperature conditions 14 I ignition sensitive 14 indicators 9 L LCD brightness 14 contrast 14 O operating system 14 operating temperature range 14 P Power button 8 Power LED 9 S speaker 10 Suspend Resume button 8 LED 10 System BIOS 17 T Temperature LED 9 touchscreen 10 ...

Page 29: ...22 MW 800 Owner s Manual U updating the System BIOS 17 user defined button 9 V Volume button 9 ...

Reviews: