Equipment Electrical Ratings
Rated Voltage:
12 Volt DC
Rated Voltage Range:
10.8 to 15.6 V DC
Rated Current:
3 Amps @ 3Watts RF power
Please be aware when planning the installation that there is a current consumption of approx. 3.5 A
during PTT and even 30 mA when terminal is switched off.
Transmitter Frequency Range:
TMO: 380–430MHz (MT912M), 410–470 MHz (MT512M)
DMO: 380–430MHz (MT912M), 410–470 MHz (MT512M)
Receiver Frequency Range:
380–430MHz (MT912M), 410–470 MHz (MT512M)
Normal Load Conditions:
Rated RF Power:
3 Watts
Rated Audio Power:
10 Watts @ 4 Ohms; 6 Watts @ 8 Ohms
Antenna Impedance:
50 Ohms
Operating Temp. Range:
-30 to +60°C
Operating Time*:
Continuous / Intermittent
*Note: In general, the terminal transmit and receive time (operating cycle time) is determined by the
communication system. On overload, respectively on extensive use beyond the systems specifications at high
ambient temperatures, the terminal is protected by its thermal control, which cuts down the RF output power,
thus reducing the terminal coverage range.
Fuse Identification
In case of blown fuses during the installation only replace those with identically value.
Never insert
different values.
Fuse for Power Cable GKN6270/GKN6274:
10 A (Motorola Part Number: 6580283E05)
Fuse for Ignition Sense Cable HKN9327:
4 A (Motorola Part Number: 6580283E02)