TEST SETUP & TESTING for 380–430 MHz and 410–470 MHz
5.1 - 3
Test Check List
The following table summarises the required test setups.
Table 5.1-2
Test Setup
No.
Test Name
Test Setup
Terminal Setup
Test Conditions
Limits
1.
IFR System Setup
and Manual Test
Screen
Control Channel
For 380–430MHz
terminal: 840
For 410–470MHz
terminal: 2440
Traffic Channel
For 380–430MHz
terminal: 840
For 410–470MHz
terminal: 2440
Time Slot
3
Country Code
262
Network Code
75
Base Color
1
Location Area
224
Min Rx Level
-110dBm
Max Tx Level
35dBm (3.2W)
Access
Parameter
-33dBm
Mobile Power
35dBm (3.2W)
Burst Type
Normal
2.
Base Station
Registration
RF Gen Level
For 380–430MHz
terminal:
421.0125MHz
For 410–470MHz
terminal:
461.0125MHz
-90dBm
3.
Receiver RSSI
RF Gen Level
Cells Info
RSSI
TRACE
-90dBm
4.
Transmitter Tests
RF Gen Level
Range 1
Test Group 1
-90dBm
Burst Power
33–37dBm
Timing Error
<=0.25 Symbols
Frequency
Error
-/+ 100Hz
Vector Error
Max 10% RMS,
Max 30% Peak,
Max 5% Residual