background image

 

 

CAUTION

RISK OF ELECTRIC SHOCK

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.

CAUTION:

 

Caution

 

These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not perform any servicing other 

than that contained in the Installation and Troubleshooting Instructions unless you are qualified to do so. Refer all servicing to qualified service 

personnel. 

Special Symbols That Might Appear on the Equipment 

 

This symbol indicates that dangerous voltage levels are present within the equipment. These voltages are not 

insulated and may be of sufficient strength to cause serious bodily injury when touched. The symbol may also 

appear on schematics. 

 

The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important 

installation, servicing, and operating instructions in the documents accompanying the equipment. 

 

For continued protection against fire, replace all fuses only with fuses having the same electrical ratings marked 

at the location of the fuse. 

 

Electrostatic discharge (ESD) can damage the MLK. Wear an antistatic wrist strap attached to a chassis ground 

to prevent ESD damage. 

 

This equipment operates over the marked Voltage and Frequency range without requiring manual setting of any 

selector switches. Different types of line cord sets may be used for connections to the mains supply circuit and 

should comply with the electrical code requirements of the country of use. 

 

CAUTION: 

TO PREVENT ELECTRICAL SHOCK, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE, OR OTHER 

OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. 

CAUTION: 

TO ENSURE REGULATORY AND SAFETY COMPLIANCE, USE ONLY THE PROVIDED POWER CABLES. 

It is recommended that the customer install an AC surge arrestor in the AC outlet to which this device is connected. This is to avoid damaging the 

equipment by local lightning strikes and other electrical surges. 

Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 

 

 

 

 

 

Summary of Contents for MINILINE 1000 Series

Page 1: ...z This Installation Sheet provides instructions on how to install the MLK amplifier in a CATV system Figure 1 illustrates a closed MLK amplifier Figure 1 Closed MLK Unpacking the MLK Unpack the MLK amplifier and inspect it for damage If damage is visible set it aside in the original packing material and contact the Motorola Customer Service Department for further instructions Verify that you have ...

Page 2: ...ut Output Connectors KS conn 5 8 24 F conn KS input and F output conn IEC input and F output conn IEC type MLK 8 G X X X Key G Technology Key A K E S Frequency Range 5 65 MHz 85 870 MHz 5 42 MHz 54 870 MHz 5 30 MHz 47 870 MHz 5 40 MHz 52 870 MHz Key S H Output level Standard output High output Before You Begin Before you install the MLK verify that the following conditions are met The MLK operatin...

Page 3: ...ee Table 1 Key 9 for description 5 Connect the output coaxial cable to the output connector on the bottom right of the MLK item 14 in Figure 3 See Table 1 Key 14 for possible types of connectors 6 If applicable use a 2 mm Allen wrench to torque the center conductor seizure screw to 6 5 to 9 in lbs 0 5 to 0 75 N m See Table 1 Key 15 for description 7 Applying power If using Model MLKL completion of...

Page 4: ...d features of the MLKM illustrated in Figure 3 Table 1 MLKM features Key Description 1 20 dB forward path input and return path output test point 2 Removable diplex filters 3 Forward path equalizer pad JXP B 4 Forward path attenuator pad JXP B 5 Forward path interstage module for tilt SEZ9 6 20 dB return path input test point 7 20 dB forward path output test point 8 Input power connector Model MLK...

Page 5: ...e upper handle portion from the pad as illustrated in Figure 4 Figure 4 JXP B attenuator pad 2 Use needle nose pliers to insert the pad in the proper location If you need to provide a sloped output you must only use interstage modules from the SEZ9 series The module you select determines the slope characteristic Changing the slope does not change the noise figure of the MLK Gain is changed by inst...

Page 6: ...1 215 323 0044 Online http www motorola com broadband click HTML Modem Version click Customer Support then click Web Support The TRC is open from 8 00 AM to 7 00 PM Eastern Time Monday through Friday and 10 00 AM to 6 00 PM Eastern Time Saturday When the TRC is closed emergency service only is available on a call back basis Web Support offers a searchable solutions database technical documentation...

Page 7: ...ment For continued protection against fire replace all fuses only with fuses having the same electrical ratings marked at the location of the fuse Electrostatic discharge ESD can damage the MLK Wear an antistatic wrist strap attached to a chassis ground to prevent ESD damage This equipment operates over the marked Voltage and Frequency range without requiring manual setting of any selector switche...

Page 8: ...ndards EN50083 1 following the provisions of the Directive s of the Council of the European Union EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC MOTOROLA and the Stylized M Logo are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2002 494330 001 8 02 All rights reserved No part of the contents of thi...

Reviews: