Figure 3 illustrates an open MLKM and the user related features: 

Figure 3  
Open MLKM 

DI SCON NE CT FR OM R EM OTE
S UP PLY   BE FORE   OP EN ING.

25 mm

1 : 1

POWER

POWER SUPPLY

V   : 24 - 65 VAC

V      : 12 VDC

I       : MAX. 1.0 A

FUSE: T2A

   REMOVE COVER
  TO CHANGE FUSE.

OUT

IN

OUT

8

SEZ

JXP IN

-20 dB

IN

RTN

EQ

FWD

EQ

H

JXP OUT

L

-20 dB

JXP IN

H

L

OUT

-20 dB

1

3

5

4

7

6

2

9 10

11

12

15

14

13

 

Table 1 identifies and describes the user-related features of the MLKM illustrated in Figure 3: 

Table 1  
MLKM features 

Key Description 

20 dB forward-path input and return-path output test point 

Removable diplex filters 

Forward path equalizer pad (JXP-*B) 

Forward path attenuator pad (JXP-* B) 

Forward path interstage module for tilt (SEZ9**) 

20 dB return-path input test point 

20 dB forward-path output test point 

Input power connector-Model MLKM only (mains powered 220 Vac to 230 Vac, 50/60 Hz) 

Input seizure screw 

10 

RF input connector options: F-type, KS, IEC 

11 

Return-path output attenuator pad (JXP-* B) 

12 

Return-path interstage equalizer pad (JXP-* B) 

13 

Return-path input attenuator pad (JXP-* B) 

Summary of Contents for MINILINE 1000 Series

Page 1: ...z This Installation Sheet provides instructions on how to install the MLK amplifier in a CATV system Figure 1 illustrates a closed MLK amplifier Figure 1 Closed MLK Unpacking the MLK Unpack the MLK amplifier and inspect it for damage If damage is visible set it aside in the original packing material and contact the Motorola Customer Service Department for further instructions Verify that you have ...

Page 2: ...ut Output Connectors KS conn 5 8 24 F conn KS input and F output conn IEC input and F output conn IEC type MLK 8 G X X X Key G Technology Key A K E S Frequency Range 5 65 MHz 85 870 MHz 5 42 MHz 54 870 MHz 5 30 MHz 47 870 MHz 5 40 MHz 52 870 MHz Key S H Output level Standard output High output Before You Begin Before you install the MLK verify that the following conditions are met The MLK operatin...

Page 3: ...ee Table 1 Key 9 for description 5 Connect the output coaxial cable to the output connector on the bottom right of the MLK item 14 in Figure 3 See Table 1 Key 14 for possible types of connectors 6 If applicable use a 2 mm Allen wrench to torque the center conductor seizure screw to 6 5 to 9 in lbs 0 5 to 0 75 N m See Table 1 Key 15 for description 7 Applying power If using Model MLKL completion of...

Page 4: ...d features of the MLKM illustrated in Figure 3 Table 1 MLKM features Key Description 1 20 dB forward path input and return path output test point 2 Removable diplex filters 3 Forward path equalizer pad JXP B 4 Forward path attenuator pad JXP B 5 Forward path interstage module for tilt SEZ9 6 20 dB return path input test point 7 20 dB forward path output test point 8 Input power connector Model MLK...

Page 5: ...e upper handle portion from the pad as illustrated in Figure 4 Figure 4 JXP B attenuator pad 2 Use needle nose pliers to insert the pad in the proper location If you need to provide a sloped output you must only use interstage modules from the SEZ9 series The module you select determines the slope characteristic Changing the slope does not change the noise figure of the MLK Gain is changed by inst...

Page 6: ...1 215 323 0044 Online http www motorola com broadband click HTML Modem Version click Customer Support then click Web Support The TRC is open from 8 00 AM to 7 00 PM Eastern Time Monday through Friday and 10 00 AM to 6 00 PM Eastern Time Saturday When the TRC is closed emergency service only is available on a call back basis Web Support offers a searchable solutions database technical documentation...

Page 7: ...ment For continued protection against fire replace all fuses only with fuses having the same electrical ratings marked at the location of the fuse Electrostatic discharge ESD can damage the MLK Wear an antistatic wrist strap attached to a chassis ground to prevent ESD damage This equipment operates over the marked Voltage and Frequency range without requiring manual setting of any selector switche...

Page 8: ...ndards EN50083 1 following the provisions of the Directive s of the Council of the European Union EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC MOTOROLA and the Stylized M Logo are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2002 494330 001 8 02 All rights reserved No part of the contents of thi...