Part Number 

Model 

Description 

831000-001-00 

MBV3-100K-HXXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-42 / 54-1003 MHz K-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, full station - 90 Volt configured - RoHS Compliant 

831000-002-00 

MBV3-100S-HSXH-F-X-R 

Starline ergonomic 1 GHz MB with 5-40 / 52-1003 MHz S-split, 3-output, 42 dB 
operational gain, QAM ADU 711 MHz gain control, 14 dB internal slope, high gain 
return, 20A fuses, FTEC surge protector, full station - RoHS Compliant 

831000-003-00 

MBV3-100K-HXXH-F-X-R 

Starline ergonomic 1 GHz MB with 5-42 / 54-1003 MHz K-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, full station - RoHS Compliant 

831000-004-00 

MBV3-100A-HXXH-F-X-R 

Starline ergonomic 1 GHz MB with 5-65 / 85-1003 MHz A-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, full station  - RoHS Compliant 

831000-005-00 

MBV3-100A-HXXH-E15-X-R 

Starline ergonomic 1 GHz MB with 5-65 / 85-1003 MHz A-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, 15A electronics module only (no housing) - RoHS 
Compliant 

831000-006-00 

MBV3-100N-HXXH-F-X-R 

Starline ergonomic 1 GHz MB with 5-85 / 104-1003 MHz N-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, full station - RoHS Compliant 

831000-007-00 

MBV3-100N-HXXH-E15-X-R 

Starline ergonomic 1 GHz MB with 5-85 / 104-1003 MHz N-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, 15A electronics module only (no housing) - RoHS 
Compliant 

831000-008-00 

MBV3-100S-HXXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-40 / 52-1003 MHz S-split, 3-output, 42 dB 
operational gain, manual gain control, 14 dB internal slope, high gain return, 20A 
fuses, FTEC surge protector, full station - 90 Volt configured - RoHS Compliant 

831000-009-00 

MBV3-100S-HAXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-40 / 52-1003 MHz S-split, 3-output, 42 dB 
operational gain, ADU 499.25 MHz gain control, 14 dB internal slope, high gain return, 
20A fuses, FTEC surge protector, full station - 90 Volt configured  - RoHS Compliant 

831000-010-00 

MBV3-100K-HAXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-42 / 54-1003 MHz K-split, 3-output, 42 dB 
operational gain, ADU 499.25 MHz gain control, 14 dB internal slope, high gain return, 
20A fuses, FTEC surge protector, full station - 90 Volt configured  - RoHS Compliant 

831000-011-00 

MBV3-100S-HSXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-40 / 52-1003 MHz S-split, 3-output, 42 dB 
operational gain, QAM ADU 711 MHz gain control, 14 dB internal slope, high gain 
return, 20A fuses, FTEC surge protector, full station  - 90 Volt configured - RoHS 
Compliant 

831000-012-00 

MBV3-100K-HSXH-F-90-R 

Starline ergonomic 1 GHz MB with 5-42 / 54-1003 MHz K-split, 3-output, 42 dB 
operational gain, QAM ADU 711 MHz gain control, 14 dB internal slope, high gain 
return, 20A fuses, FTEC surge protector, full station - 90 Volt configured - RoHS 
Compliant 

 

 

 

535723-001 

SFE-100-0-R 

Starline Forward 1003 MHz equalizer (0 dB)  -or- 

MBV3 Ordering Information 

 

 
 
 
Motorola, Inc. 
101 Tournament Drive 
Horsham, PA 19044 

www.motorola.com/broadband

 

 
 

 
10.09.08 
Rev 3 

 

 

MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office. 

All other product or service names are the property of their respective owners. 

© 

Motorola, Inc. 2006. All rights reserved. 

 

Specifications are subject to change without notice. 

 

 

7

Summary of Contents for MBV3-100S

Page 1: ...ANCED GALLIUM ARSENIDE The MBV3 uses Enhanced Gallium Arsenide E GaAs hybrids This second generation technology provides superior distortion performance in CTB and CSO over the standard GaAs technology Compared to silicon and competing GaAs technology E GaAs distortion performance remains linear at significantly higher output levels This higher output level allows the customer to maximize system p...

Page 2: ...her ensure system flexibility installation ease and maintenance the amplifier is engineered for compatibility with standard accessories such as attenuators equalizers return amplifiers automotive fuses and FTEC crowbar circuits The MBV3 uses modular diplex filters which can be changed for a different frequency split as required The amplifier is available with S split filters for a 5 40 MHz return ...

Page 3: ...03 5 40 Flatness dB 2 0 5 0 5 Minimum Full Gain dB 3 46 NA Operational Gain dB 4 42 20 Manual Bode Slope Control Range dB 5 4 NA Interstage Equalizer Slope dB 6 14 1 NA Noise Figure 40 52 1003MHz dB 7 NA 10 10 8 NA NA Test Point all dB 13 20 1 0 Return Loss dB 14 16 Hum Modulation dBc 15 20 60 DC Voltage VDC 16 24 0 25 Current DC mA 17 1900 DC Ripple mV 15 p p Power Consumption W 62 AC Input Volta...

Page 4: ...4 37 36 35 28 Channel loading 79 NTSC 79 NTSC Data loading MHz 450 450 CTB dBc 76 5 86 9 21 23 CSO dBc 71 76 10 21 XM dB 68 5 78 9 11 21 NTSC CIN dBc 70 70 12 Bridger out Trunk out 9dB Reference Frequency MHz 1003 599 48 1003 599 48 8 Output level dBmV 45 45 37 36 36 28 Channel loading 65 B G 65 B G Data loading MHz 400 MHz 400 MHz CTB dBc 76 5 86 5 9 21 23 CSO dBc 71 76 10 21 XM dB 68 5 78 5 9 11...

Page 5: ...eferences the worst case channel Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS 10 Measured with wave analyzer and synchronous 100 depth modulated channels References the worst case channels over specified temperature range Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTI...

Page 6: ...MDR HPF Hybrid Drive Bode Bode ADU Tilt S JXP Comp Motorola Inc 101 Tournament Drive Horsham PA 19044 www motorola com broadband 10 09 08 Rev 3 MOTOROLA the Stylized M Logo STARLINE Mini Bridger and LIFELINE are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2006 All rights reserved Specifications are subject...

Page 7: ...gh gain return 20A fuses FTEC surge protector 15A electronics module only no housing RoHS Compliant 831000 008 00 MBV3 100S HXXH F 90 R Starline ergonomic 1 GHz MB with 5 40 52 1003 MHz S split 3 output 42 dB operational gain manual gain control 14 dB internal slope high gain return 20A fuses FTEC surge protector full station 90 Volt configured RoHS Compliant 831000 009 00 MBV3 100S HAXH F 90 R St...

Page 8: ...J split 5 65 A split values 0 12 dB in 1 dB steps for S split 2 dB steps for all other frequency splits 531186 XXX 00 JXP B R Plug in attenuator pad values 0 to 26 dB in 1 dB steps 535723 001 SFE 100 0 R Starline Forward 1003 MHz equalizer 0 dB or 558958 001 00 QADU 609 V R QADU 609 00S V R MBV3 VERTICAL AUTOMATIC DRIVE UNIT WHICH USES QAM CHANNEL AS PILOT SIGNAL SAW FILTER DESIGN CONFIGURABLE OPT...

Page 9: ...andard 4 ICS and status monitor transponders will be available as an accessory option Motorola Inc 101 Tournament Drive Horsham PA 19044 www motorola com broadband 10 09 08 Rev 3 MOTOROLA the Stylized M Logo STARLINE Mini Bridger and LIFELINE are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2006 All rights ...

Reviews: