Motorola MBV3-100S Specifications Download Page 5

 

 
 
 
Motorola, Inc. 
101 Tournament Drive 
Horsham, PA 19044 

www.motorola.com/broadband

 

 
 

 
10.09.08 
Rev 3 

 

 

MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office. 

All other product or service names are the property of their respective owners. 

© 

Motorola, Inc. 2006. All rights reserved. 

 

Specifications are subject to change without notice. 

 

 

5

 
Specification Notes: 
 

  1.        Operating passband of station.  Diplex filters are plugged into the electronic chassis. 
  2. 

Referenced to the average gain across the stated passband.   

  3. 

Minimum full gain at 1003 MHz includes loss of equalizer but Bode slope reserves have not been set.  Return gain includes loss of SRE-*-4 return equalizer.   

  4. 

Operational gain includes loss of slope reserves as well as equalizer.  

  5. 

Amount of Bode slope control range from midpoint (typical setting is -4 dB at 1003 MHz @ 20°C).  This control should not be used for gain reduction. 

  6. 

Amount of slope created and cable equivalence of fixed interstage equalizer.  Interstage equalizer is a plug-in. 

  7. 

Noise Figure is specified at the cable entry facility of the housing and includes the loss of 1 dB for the pre-stage equalizer.  The return Noise Figure includes the station loss preceding the RF 
hybrid.   

  8. 

Frequencies that relate the picture carriers or passband edges to the specified output levels and tilts. 

  9. 

Measured with CW carriers and spectrum analyzer over specified temperature range.

   

References the worst-case channel.  Specifications are compliant with the test methods as stated in 

NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS. 

10. 

Measured with wave analyzer and synchronous, 100% depth modulated channels.  References the worst-case channels over specified temperature range.  Specifications are compliant with 
the test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS. 

11. 

Composite Second Order distortion refers only to those beat clusters that fall +0.75 MHz and +1.25 MHz above the subject picture carrier.  CSO beat clusters that have a -0.75 MHz and -1.25 
MHz relationship to the subject picture carrier are not included in this specification. 

12. 

Carrier / Composite Intermodulation Noise Ratio 

13. 

Test points should be used with GFAL adaptor. 

14. 

Match measurement at the station input and output, cable-entry facilities, at the specified passbands for operational gain. 

15. 

Measured with the stated AC Bypass Current. 

16. 

Measured at the power connector. 

17. 

Current draw at +24.0 VDC. 

18. 

AC current is stated in RMS continuous.   

19. 

Group Delay is specified for standard NTSC video, where delay is the delta from picture carrier to 3.58 MHz color subcarrier.  Reverse delay is in a 1.5 MHz bandwidth. 

20. 

Distortion numbers are worst case over temperature in a cascade.  

21. 

The compressed data loading is QAM carriers and are –6 dB  relative to the analog CW carriers. 

22. Note 

placeholder 

23. 

CTB (Composite Triple Beat).  At the specified channel loading, Enhanced Gallium Arsenide performance varies on a two point three-for-one (2.3:1) basis with amplifier output level.   

         

Summary of Contents for MBV3-100S

Page 1: ...ANCED GALLIUM ARSENIDE The MBV3 uses Enhanced Gallium Arsenide E GaAs hybrids This second generation technology provides superior distortion performance in CTB and CSO over the standard GaAs technology Compared to silicon and competing GaAs technology E GaAs distortion performance remains linear at significantly higher output levels This higher output level allows the customer to maximize system p...

Page 2: ...her ensure system flexibility installation ease and maintenance the amplifier is engineered for compatibility with standard accessories such as attenuators equalizers return amplifiers automotive fuses and FTEC crowbar circuits The MBV3 uses modular diplex filters which can be changed for a different frequency split as required The amplifier is available with S split filters for a 5 40 MHz return ...

Page 3: ...03 5 40 Flatness dB 2 0 5 0 5 Minimum Full Gain dB 3 46 NA Operational Gain dB 4 42 20 Manual Bode Slope Control Range dB 5 4 NA Interstage Equalizer Slope dB 6 14 1 NA Noise Figure 40 52 1003MHz dB 7 NA 10 10 8 NA NA Test Point all dB 13 20 1 0 Return Loss dB 14 16 Hum Modulation dBc 15 20 60 DC Voltage VDC 16 24 0 25 Current DC mA 17 1900 DC Ripple mV 15 p p Power Consumption W 62 AC Input Volta...

Page 4: ...4 37 36 35 28 Channel loading 79 NTSC 79 NTSC Data loading MHz 450 450 CTB dBc 76 5 86 9 21 23 CSO dBc 71 76 10 21 XM dB 68 5 78 9 11 21 NTSC CIN dBc 70 70 12 Bridger out Trunk out 9dB Reference Frequency MHz 1003 599 48 1003 599 48 8 Output level dBmV 45 45 37 36 36 28 Channel loading 65 B G 65 B G Data loading MHz 400 MHz 400 MHz CTB dBc 76 5 86 5 9 21 23 CSO dBc 71 76 10 21 XM dB 68 5 78 5 9 11...

Page 5: ...eferences the worst case channel Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS 10 Measured with wave analyzer and synchronous 100 depth modulated channels References the worst case channels over specified temperature range Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTI...

Page 6: ...MDR HPF Hybrid Drive Bode Bode ADU Tilt S JXP Comp Motorola Inc 101 Tournament Drive Horsham PA 19044 www motorola com broadband 10 09 08 Rev 3 MOTOROLA the Stylized M Logo STARLINE Mini Bridger and LIFELINE are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2006 All rights reserved Specifications are subject...

Page 7: ...gh gain return 20A fuses FTEC surge protector 15A electronics module only no housing RoHS Compliant 831000 008 00 MBV3 100S HXXH F 90 R Starline ergonomic 1 GHz MB with 5 40 52 1003 MHz S split 3 output 42 dB operational gain manual gain control 14 dB internal slope high gain return 20A fuses FTEC surge protector full station 90 Volt configured RoHS Compliant 831000 009 00 MBV3 100S HAXH F 90 R St...

Page 8: ...J split 5 65 A split values 0 12 dB in 1 dB steps for S split 2 dB steps for all other frequency splits 531186 XXX 00 JXP B R Plug in attenuator pad values 0 to 26 dB in 1 dB steps 535723 001 SFE 100 0 R Starline Forward 1003 MHz equalizer 0 dB or 558958 001 00 QADU 609 V R QADU 609 00S V R MBV3 VERTICAL AUTOMATIC DRIVE UNIT WHICH USES QAM CHANNEL AS PILOT SIGNAL SAW FILTER DESIGN CONFIGURABLE OPT...

Page 9: ...andard 4 ICS and status monitor transponders will be available as an accessory option Motorola Inc 101 Tournament Drive Horsham PA 19044 www motorola com broadband 10 09 08 Rev 3 MOTOROLA the Stylized M Logo STARLINE Mini Bridger and LIFELINE are registered in the US Patent Trademark Office All other product or service names are the property of their respective owners Motorola Inc 2006 All rights ...

Reviews: