DEBUG MONITOR COMMANDS
M68CPU32BUG/D REV 1
3-55
RD
Register Display
RD
The source and destination function code registers (SFC, DFC) include a two character
mnemonic:
Function Code
Mnemonic
Description
0
F0
Undefined
1
UD
User Data
2
UP
User Program
3
F3
Undefined
4
F4
Undefined
5
SD
Supervisor Data
6
SP
Supervisor Program
7
CS
CPU Space
To set the display to D6 and A3 only.
CPU32Bug>RD =D6/A3<CR>
D6 =00000000 A3 =00000000
00003000 4AFC ILLEGAL
CPU32Bug>
Note that the above sequence sets the display to D6 only and then adds register A3 to the display.
To restore all the MPU registers.
CPU32Bug>rd +mpu<CR>
PC
=00003000
SR
=2700=TR:OFF_S_7_.....
VBR
=00000000
SFC
=0=F0
DFC
=0=F0
USP
=00003830
SSP*
=00004000
D0
=00000000
D1
=00000000
D2
=00000000
D3
=00000000
D4
=00000000
D5
=00000000
D6
=00000000
D7
=00000000
A0
=00000000
A1
=00000000
A2
=00000000
A3
=00000000
A4
=00000000
A5
=00000000
A6
=00000000
A7
=00004000
00003000 4AFC ILLEGAL
CPU32Bug>