FIELD LEVEL TEST MODES AND PROCEDURES:
Registration/Call Test
8-4
68P80400P73-
A
8.4
Registration/Call Test
Use this test on a unit having any of the following symptoms: No Service failures, Please Wait...
Registering failures. (Use a reference unit to get a baseline.)
Replace the
Main board.
Fail
Set up the R-2660 for
i
DEN
Mobile operation, and connect the
unit to the RF IN/OUT connector.
See Figure 7-1 on page 7-3.
Pass
OK
Fail
Fail
Pass
Notes:
1.
See the
Strong Signal Environment
section.
2.
Master reset can be completed on the unit by pressing
Menu,
Settings, Security
.
3.
Registration and calls might take over 1 minute to complete.
4.
Make sure the R-2660 is set to a frequency in the radio bandmap.
Unit passed test. Look for
system, coverage, accessory,
or software problems.
Pass
Power up
the unit. Enter initial
Registration mode (see
Operating the R-2660
). Press
Start
.
The
Call SEQ
: 1 thru 6 lights up
when the unit has
registered.
Verify the
unit can complete
an interconnect call. Press
End/Home
until unit displays
Ready
. Press
Interconnect
(3:1 or 6:1)
and
Start
on the R-2660. Press
Send
on the unit. The
Call SEQ
: 1 thru 8
lights up when the unit has
entered Phone
mode.
Verify the
R-2660 calibration, setup,
and cable continuity.
Fix, if necessary.
Verify the
unit is programmed
for Half Rate if attempting
a 3:1 phone call or Full Rate if
attempting a 6:1 phone
call. Repeat the
test.
Note:
For 900 MHz verification, please perform the BER Test. May require ordering additional option for test.
Contact Motorola Customer Service (see Appendix A).
Perform
BER Test.
Pass
Fail
Summary of Contents for i860
Page 1: ......
Page 35: ...This page intentionally left blank ...
Page 37: ...This page intentionally left blank ...
Page 51: ...This page intentionally left blank ...
Page 75: ...PREPARING FOR FIELD LEVEL TESTING Flip Assembly 7 14 68P80400P73 A Figure 7 20 Figure 7 21 ...
Page 79: ...This page intentionally left blank ...