MODEL CHART AND TEST SPECIFICATION
5.2
GP344/388
Data is specified for +25°C unless otherwise stated.
General Specifications
Channel Capacity
GP344
GP388
16
255
Power Supply
Rechargeable battery 7.5v
Dimensions: H x W x D (mm)
With standard Lilon battery
With high capacity Lilon battery
Height excluding knobs
GP344
GP388
101.5 x 55.5 x 30.5
101.5 x 55.5 x 33.0
101.5 x 55.5 x 35.5
101.5 x 55.5 x 38.0
Weight: (gm)
With Standard Lilon battery
With high capacity Lilon battery
GP344
GP388
250
265
270
285
Average Battery Life @5/5/90 Cycle:
With Standard Lilon battery
With high capacity Lilon battery
Low Power
High Power
>9 hours
>7 hours
>13 hours
>10 hours
Sealing:
Withstands rain testing per
MIL STD 810 C/D /E and IP54
Shock and Vibration:
Protection provided via impact
resistant housing exceeding MIL STD
810-C/D /E and TIA/EIA 603
Dust and Humidity:
Protection provided via environment
resistant housing exceeding MIL STD
810 C/D /E and TIA/EIA 603