User Preferences & Miscellaneous Digital Scanner Options 4 - 39
Multicode Expression
Parameter # F1h, 95h
Use this feature to program a multicode expression for
(grid method). The default is 1, which
indicates any bar code.
To set the multicode expression:
1.
Scan the bar code below.
2.
Scan bar codes from the alphanumeric keyboard in the
Advanced Data Formatting Programmer Guide
to
define the expression.
3.
Scan the
End of Message
bar code from the
Advanced Data Formatting Programmer Guide.
Multicode Expression Syntax: [n] [Element 1]; [Element 2 ]; ... [Element n];
Where
n
is the number of elements in the overall expression.
The multicode expression describes the bar code(s) that the digital scanner can expect to find in an image. Each
element represents one bar code in the digital scanner's field of view. The order of elements in the expression is
the order in which bar code data from each element transmits to the host. Elements are defined using one or more
of the following methods:
By Region
. This type of element limits decoding to a specific area within the digital scanner's field of view. Region
coordinates are defined as the top left and bottom right corners of the region, expressed in percentages of the field
of view. These can range from 0% to 100%, or 0x00 to 0x64 in hex, for both horizontal and vertical axes. A region
element is constructed as:
[R] [4] [Top, Left] [Bottom, Right]
Where:
•
[R] is the character R
•
[4] is 0x04, indicating there are four bytes thereafter to describe the region
•
[Top, Left] are two values representing the top left corner of the region
•
[Bottom, Right] are two values representing the bottom right corner of the region
By Code Type
. An element can specify a specific bar code symbology to find and decode somewhere in the field of
view. A code type element is constructed as:
[C] [2] [Code Type]
Where:
•
[C] is the character C
•
[2] is 0x02, indicating there are two bytes thereafter to describe the code type
•
[Code Type] is the desired symbology's parameter number (see
). For single-byte
parameter numbers, extend the value to two bytes by adding 00 before the parameter number.
Multicode Expression
Summary of Contents for DS9808 - Symbol - Wired Handheld Barcode Scanner
Page 1: ...Symbol DS9808 Digital Scanner Product Reference Guide ...
Page 2: ......
Page 3: ...Symbol DS9808 Digital Scanner Product Reference Guide 72E 112999 04 Revision A April 2010 ...
Page 16: ...xiv Symbol DS9808 Product Reference Guide ...
Page 26: ...1 6 Symbol DS9808 Product Reference Guide ...
Page 42: ...3 8 Symbol DS9808 Product Reference Guide ...
Page 116: ...5 22 Symbol DS9808 Product Reference Guide ...
Page 142: ...6 26 Symbol DS9808 Product Reference Guide ...
Page 224: ...10 32 Symbol DS9808 Product Reference Guide ...
Page 310: ...12 2 Symbol DS9808 Product Reference Guide ...
Page 354: ...13 44 Symbol DS9808 Product Reference Guide ...
Page 366: ...A 12 Symbol DS9808 Product Reference Guide ...
Page 374: ...B 8 Symbol DS9808 Product Reference Guide ...
Page 375: ...Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5 ...
Page 378: ...C 4 Symbol DS9808 Product Reference Guide Maxicode QR Code US Postnet UK Postal ...
Page 414: ......
Page 415: ......