MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Troubleshooting: BRC Con
fi
g Files and Code File
Table 13-4
Site Reference States - status bts (Continued)
Site Reference State
Explanation
EXT
Reports on con
fi
gured EAS alarms and will advise which alarm contact
is active
FAN
Reports status of the fan kits
MTS
Gives the status of the site, whether it is in Wide, Site or No Trunking and a
reason for example ’No Control Channel’
PSU
Reports on status of the power supply module and reports trap state of ’PSU
Input Fault’ with reason ’Power Supply Battery Voltage Failure’
SCINT
Module fault
SCPORT
Status of the Site Controllers ethernet ports
SCREF
Gives status of the GPS signal and timing
Troubleshooting: BRC Config Files and Code File
The BRC will not boot or operate correctly unless a valid con
fi
guration
fi
le and code
fi
le is stored in
the
fl
ash
fi
ling system of the Site Controller. Use the method described in General Check of a Site
Controller File to ensure that the
fi
le shown in the following table is valid for the BR of interest. For
Code File ensure that either brc.code.1 or brc.code.2 is selected as current
fi
le
Con
fi
g
fi
les will only normally be present for installed BRCs.
Table 13-5
BRC Config File Troubleshooting
BR Cabinet
BR Position
Filename
1
1
brc01.cf
1
2
brc02.cf
2
1
brc03.cf
2
2
brc04.cf
6802800U74-N September 2009
13-7
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...