2-6
DSP56F807EVM Hardware User’s Manual
2.3 RS-232 Serial Communications
The DSP56F807EVM provides an RS-232 interface by the use of an RS-232 level
converter, (Maxim MAX3245EEAI, designated as U13). Refer to the RS-232 schematic
diagram in
. The RS-232 level converter transitions the SCI UART’s 3.3V
signal levels to RS-232 compatible signal levels and connects to the host’s serial port via
connector P3. Flow control is not provided, but could be implemented using uncommitted
GPIO signals. The pinout of connector P3 is listed in
. The RS-232 level
converter/transceiver can be disabled by placing a jumper at JG9.
Figure 2-2. Schematic Diagram of the RS-232 Interface
.
Table 2-1. RS-232 Serial Connector Description
P3
Pin #
Signal
Pin #
Signal
1
Jumper to 6 & 4
6
Jumper to 1 & 4
2
TXD
7
Jumper to 8
3
RXD
8
Jumper to 7
4
Jumper to 1 & 6
9
N/C
5
GND
DSP56F807
RS-232
Level Converter
Interface
TXDO
RXDO
R1in
T1out
T1in
R1out
FORCEOFF
JG9
1
2
6
3
2
7
8
4
5
x
1
9
+3.3V
Jumper Removed:
Enable RS-232
Jumper Pin 1-2:
Disable RS-232
Summary of Contents for Digital DNA DSP56F807
Page 2: ......
Page 12: ...xii DSP56F807EVM Hardware User s Manual ...
Page 53: ... DSP56F807EVM Schematics A 1 Appendix A DSP56F807EVM Schematics ...
Page 72: ...A 20 DSP56F807EVM Hardware User s Manual ...
Page 79: ......