![Motorola DCT6400 Series Installation Manual Download Page 53](http://html.mh-extra.com/html/motorola/dct6400-series/dct6400-series_installation-manual_244451053.webp)
4-22
Diagnostics
DCT6400 Series Installation Manual
Field Description
Max Temp
For an internal hard drive
only
, its maximum temperature in degrees F.
Over Temp
Yes — The internal drive temperature exceeds 60º C. The LED Over-Temp Indicator
is on and remains lit until the next over-temp sample is taken (at least once an hour).
No — There is no over temp problem.
Count
The cumulative number of times that the hard drive temperature exceeds 60º C, with the
temperature checked at least once an hour.
d14 Interactive Info
This diagnostic describes the interactive information that is displayed only when Thin Client
platform is running. The information on the OSD and LED is updated at least once every 5
seconds while the diagnostic is displayed. This is an example of a code module display with
status descriptions:
INTERACTIVE INFO
IP ADDRESS:
UPM:
UPSTREAM ID:
DOWNSTREAM ID:
STATE:
MAC ABORT CNTR:
0.0.0.0
00000021
0000
0000
UNCONFIG
0000
SOCKET PORT STATE:
0
UNUSED
1
UNUSED
2
UNUSED
3
UNUSED
4
UNUSED
Figure 4-10
Interactive Info LED display
MUTE
MUTE
P
P
The Interactive Info fields are:
Field Description
IP Address
The IP address in dotted-decimal format
xxx.xxx.xxx.xxx
assigned by the NC 1500 to the
set-top. 0.0.0.0 is displayed if the IP address is not configured or unknown.
UPM
The upstream modem address value is the same as the terminal ID assigned by the
DAC 6000. It is a unique, system-generated, eight-digit integer between 1 and 16777215.
00000000
is displayed when the UPM is not configured or unknown.
Upstream ID
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the set-top.