Motorola Canopy 300SS-UG-E User Manual Download Page 7

PLACEMENT 

The following are 2 descriptions of different installation placements, using the Canopy Surge Suppressor 
in combination with other Canopy products. (Subscriber Module, Cluster Management Module, and 
BackHaul module). 

With a Subscriber Module 

The Surge Suppressor is installed on the outside of the buiding between the Subscriber Module and the 
computing equipment. 
 
 
 

Wiring Diagram of Canopy Subscriber Module to Computer with Surge Suppressor 

 
 

Computer

SM

AC adapter

outside wall

Ethernet cable

Surge

 Suppressor

grounding

system

Ethernet cable

 

 

 

 

With an Access Point Module, Cluster Management Module, or BackHaul 
Module 

 
The Surge Suppressor is installed between the Canopy equipment and the networking equipment.  For 
instance, if a network feed is being introduced into the Cluster Management Module, the Surge 
Suppressor must be placed on the Ethernet cable from the networking equipment (switch/router) to the 
Cluster Management Module. 

 
 
 
 
 

Page 7 

Summary of Contents for Canopy 300SS-UG-E

Page 1: ...Canopy Surge Suppressor User Manual 300SS UG E R 02 02 2002 Motorola Inc All rights reserved Printed in the U S A ...

Page 2: ...onnected to an antenna grounding system installed according to Section 810 or 820 of the National Electric Code ANSI NFPA No 70 1993 If you have any doubt about your antenna grounding system contact a licensed electrician MOTOROLA the stylized M Logo and all other trademarks indicated as such herein are trademarks of Motorola Inc Reg U S Pat Tm Office Canopy is a trademark of Motorola Inc All othe...

Page 3: ...RTED 4 WELCOME 4 INTENDED USE 4 WARRANTY 4 PRODUCT DESCRIPTION 5 INSTALLATION 6 PREPARATION 6 PROCEDURE 6 PLACEMENT 7 With a Subscriber Module 7 With an Access Point Access Point Installation Kit BackHaul 7 SPECIFICATIONS 8 Page 3 ...

Page 4: ...e by the retail customer If a product is found defective during the warranty period Motorola will repair or replace the product with the same or a similar model which may be a reconditioned unit without charge for parts or labor IN NO EVENT SHALL MOTOROLA BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT INDIRECT GENERAL SPECIAL INCIDENTAL CONSEQUENTIAL EXEMPLARY OT OTHER DAMAGE ARISING OUT OF TH...

Page 5: ...rface such as an outside wall The distance between the centers of the holes is 4 25 inches 108 mm 2 RJ45 connectors One side connects to the Canopy product the other side connects to the AC adaptor s Ethernet connector 3 Ground post use heavy gauge 10 AWG copper wire for connection Refer to local electrical codes for exact specifications 1 1 2 2 3 FIGURE 1 Page 5 ...

Page 6: ...t an Ethernet cable between the power adapter Ethernet socket pig tail and either end of the RJ45 sockets on the Canopy Surge Suppressor 4 Connect an Ethernet cable between the other RJ45 socket on the Canopy Suppressor and the RJ45 socket on the Canopy product 5 Connect ground wire by wrapping it around the ground post and tightening the locking nut The ground wire should be made of heavy gauge A...

Page 7: ...Wiring Diagram of Canopy Subscriber Module to Computer with Surge Suppressor Computer SM AC adapter outside wall Ethernet cable Surge Suppressor grounding system Ethernet cable With an Access Point Module Cluster Management Module or BackHaul Module The Surge Suppressor is installed between the Canopy equipment and the networking equipment For instance if a network feed is being introduced into th...

Page 8: ... 127 mm x D 43 2 mm Space between mounting holes 4 25 108 mm Size of knockouts 0 75 19 mm Weight 0 4 lbs 180 g Operating Temperature 40ºC to 55ºC 40ºF to 131ºF Internal Connectors RJ45 Capacity 1500J peak pulse energy dissipation with 10 10000µs waveform Page 8 ...

Reviews: