13A
13B
EN
EN
RTX 2252-SENSOR MODULE (OPTIONAL)
• CONSUMER OPERATION
Energy saving is disabled = OFF
This function should be used only when
there is a considerable distance between
RTX 2252 and 2278 sensor because it has
a very high batteries consumption.
Energy saving enabled=ON
The sensor’s transmission power is sli-
ghtly
lower, decreasing the radio capacity,
which can affect the settings at installa-
tion time.
ON
OFF
ON
OFF
1
2
SW2
ON
OFF
ON
OFF
1
2
SW2
It is possible to select two different consumption patterns in the functioning of RTX2252
(SENSOR) devices.
NOTE:
When the battery is discharged, the TX LED from the RTX 2252 sensor will get a
quick intermittency signal. At that point it sends signal to the RTX 2278 (Base) device,
which will act as indicated on
page 9A
.
• When the RTX 2252 Device (sensor) is removed from an installation, it is advisable
to remove the batteries to prevent the sensor continues to transmit uselessly
• It is advisable to replace device stacks immediately in the presence of a flashing
TX LED
.
03. CONFIGURATION
04. COMPONENTS TEST
SCHEMES FOR CAPACITORS
To detect which components have problems during a sliding automatism installation,
sometimes it's necessary to conduct tests with a direct connection to a 110V or 230V
power supply. For this, it's necessary to interpose a capacitor on the connection so that
the motor can work (check the capacitor type to be used in the product's manual). In
the below diagram is shown how this connection must be made and how to merge the
different component wires.
NOTES:
• To perform the tests you don't need to remove the automatism from it's place, because
this way you can understand if the automatism, directly connected to the power, can
function correctly.
• The order of capacitor wires linked with the automatism wires are not important, as
long as you link, one to the Brown wire and the other to the Black one;
• The common wire of the motor must always be connected to the power supply;
• To reverse the automatism functioning direction, switch the Black wire with the Brown
wire of the automatism.
All tests must be performed by skilled technicians due to serious danger
associated with the misuse of electrical systems!!
CAPACITATOR
MOTOR
110V or 230V
POWER
SUPPLY
Ground wire
Brown
Black
Common (Blue)
01