3A

EN

• Attach the permanent label for the manual release as close as possible 

to the release mechanism.

• Disconnect means, such as a switch or circuit breaker on the electrical 

panel, must be provided on the product’s fixed power supply leads in 

accordance with the installation rules.

• If the product to be installed requires power supply of 230Vac or 

110Vac, ensure that connection is to an electrical panel with ground 

connection.

•The product is only powered by low voltage satefy with central (only 

at 24V motors)

WARNINGS FOR USERS

• Keep this manual in a safe place to be consulted whenever necessary.

• If the product has contact with fluids without being prepared, it must 

immediately disconnect from the power supply to avoid short circuits, 

and consult a specialized technician.

• Ensure that technician has provided you the product manual and 

informed you how to handle the product in an emergency.

• If the system requires any repair or modification, unlock the automatism, 

turn off the power and do not use it until all safety conditions have 

been met.

• In the event of tripping of circuits breakers of fuse failure, locate 

the malfunction and solve it before resetting the circuit breaker or 

replacing the fuse. If the malfunction is not repairable by consult this 

manual, contact a technician.

• Keep the operation area of the motorized gate free while the gate in in 

motion, and do not create strength to the gate movement.

• Do not perform any operation on mechanical elements or hinges if the 

product is in motion.

RESPONSABILITY

• Supplier disclaims any liability if:

• Product failure or deformation result from improper installation 

use or maintenance!

• Safety norms are not followed in the installation, use and 

maintenance of the product.

• Instructions in this manual are not followed.

• Damaged is caused by unauthorized modifications

• In these cases, the warranty is voided.

01. SAFETY INSTRUCTIONS

SYMBOLS LEGEND:

• Important safety 

notices

• Useful information

• Programming 

information

• Potentiometer 

information

• Connectors 

information

• Buttons 

information

Summary of Contents for MLS4

Page 1: ...V1 2 REV 10 2021 MLS4 MLS4 EN USER INSTALLER MANUAL...

Page 2: ...or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household waste at the end of its useful l...

Page 3: ...with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorize...

Page 4: ...esanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the ma...

Page 5: ...tputreader Two devices interlocked Two devices can be interlocked online Anti passback Single door or two doors anti passback TECHNICAL SPECIFICATIONS Power Supply 12Vdc 10 Static current 30mA Card ma...

Page 6: ...CONNECTIONS 03 INSTALLATION AND CONNECTIONS STANDALONE FOR A DOOR WITH POWER SUPPLY 12Vdc power supply 12Vdc power supply Electric lock Electromagnetic lock Exit Button Exit Button External reader Ex...

Page 7: ...appen operations within 10seconds the device will enter working mode automatically and the parameter reset to factory default Add users by remote control ADMIN SETTING ON KEYPAD Entering admin operati...

Page 8: ...INSTALLATION Set Red light mode Add user Delete user Set Interlock Set Anti passback Static off mode Press Press Press Close interlock factory default Press Disable anti passback factory default Press...

Page 9: ...ved data can t be shared between different devices This function mainly apply for bank prison etc 3 Anti passback for Single door Install a common reader outdoor or use this device without any card No...