SETTING STRENGTH AND SENSITIVITY
If the control board has very high sensitivity values, you may see the
LI
error.
After four attempts, the
LI
error will turn
ER
.
You will have to wait 10 sec. to return to program the automatism.
Sensitivity adjustment
It allows you to adjust the engine sensitivity in detecting obstacles. The higher the
sensitivity the less effort is needed to detect any obstacle and reverse the direction.
(Factory default
05
)
min.
max.
1
9
07
• P3 appears
(disable menu).
To program P4,
continue in step
3 from P4 menu
(page 7B). To exit the
programming press
↑↓
simultaneously.
04. PROGRAMMING "P"
07
• P5 appears.
To program P5, continue in step 3 from P5 menu (page 8A).
To exit the programming press ↑↓ simultaneously.
Pause time adjustment
of the total closure
Allows you to set the
time that the gate
will remain open.
(factory default
10sec.
)
99s
min.
max.
1s
01
• Press MENU for 3
seconds.
When the values
are zero, the a
utomatic closing
ceases to exist
03
• P4 appears.
Press MENU for 3
seconds.
02
• P0 appears.
Press four times.
04
• AF appears.
Press MENU for 3
seconds.
05
• Appears the time
set from factory. If
you want, change
time between 1 and
99 sec., using ↑↓.
06
• Press MENU for
3 seconds
to save
the defined time.
PAUSE TIME
04. PROGRAMMING "P"
P3 MENU DISABLE.