Vertical level operation (90°)
1. When the level is placed on a surface to determine a vertical
surface (90 0.1°), the vertical vial (left of On/Off button) will
light solid GREEN and the tool will beep 3 times.
2. If the surface is slightly off-vertical (= between 0.1° and 0.5°
from 90°), which is acceptable for most applications, the
vertical vial will flash GREEN continuously.
3. If the surface is not acceptably vertical (more than 0.5° from
90°), the vertical vial will light up solid RED.
Sleep Function
When the level is idle for 60 seconds all of the electronic functions
automatically turn off. Press the On/Off button for 1 to 2 seconds
to turn electronic functions back on.
Low Battery Power Indication
When battery power falls below what is needed for proper tool
electronic functionality, the top vial will flicker RED to indicate that
the batteries need to be replaced.
Level Calibration
The level has been calibrated at the factory prior to shipment.
However, circumstances such as the process of shipping and
handling, or dropping the level onto a hard surface, may cause it
to fall out of calibration. To recalibrate the level, perform the
following procedure.
Note:
The calibration shall be operated on horizontal platform.
16" LED Level
(MH-02-LL-B1-16-1)