6. Starting with the positive (+) lead, reconnect the battery cables to the engine
starting or accessory battery.
24-volt battery connection
a -
Power cables to trolling motor
b -
Manual reset circuit breaker
c -
Jumper wire (not supplied)
d -
Negative (–) battery terminal
36-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the
engine starting or accessory battery.
2. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in line
with the trolling motor power cable positive (+) lead and the trolling motor
battery
C
positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on trolling
motor battery
C
.
4. Connect a jumper wire (reference gray) between the negative (–) terminal on
battery
C
to the positive (+) terminal on battery
B
.
IMPORTANT: The jumper wire should be the same wire gauge as the negative (–)
and positive (+) power cables.
5. Connect a jumper wire (reference gray) between the negative (–) terminal on
battery
B
to the positive (+) terminal on battery
A
.
RED
BLACK
a
b
c
d
37824