Pic #41 Hydraulic Schematic
Start-Up Procedures:
Manually turn on
your
HYDRAULIC POWER UNIT
and set the hydraulic flow control valve to a
WHEEL
SPEED OF 85 TO 90 RPM
for a
MINIWRAP™
using
COTTON CLOTH™.
You may use a non-contact
tachometer to accurately measure RPM,
or by placing a piece of tape on the cloth/foam and counting
the rotations per 15 seconds. Multiply this by 4 to calculate current RPM.
If
your
MINIWRAP™
is equipped with
C-CHANNEL FOAM,
set the
WHEEL SPEED
between
88 to 90
RPM.
Check
all hydraulic lines for leaks. Turn the hydraulic power unit OFF.
NOTE:
IF THE MINIWRAP™ IS ELECTRIC DRIVE, THE WHEEL
SPEED IS PRESET AT 88 RPM. USING A VARIABLE SPEED DRIVE
(VFD), INSTEAD OF STARTER UNITS, ALLOWS FOR WHEEL SPEED
ADJUSTMENTS. REFER TO RECOMMENDATIONS ABOVE FOR
OPTIMAL WHEEL SPEED ADJUSTMENT.
Set
the
DRIVER’S SIDE ARM
air pressure at
35 PSI
and the
PASSENGER’S SIDE ARM
air pressure at
60 PSI.
MANUALLY TURN ON
the
STREAMER SOAP FOAMER DILUTION STATION
to the wrap, adjust the
foamers and position the
STREAMER HEADS TO SPRAY THE FOAM TOWARD EACH WHEEL.
Turn
OFF the dilution station. Consult your MCWW Dilution Station Installation manual for adjustment.
Manually turn on
the
WATER DILUTION STATION
and adjust the
SPRAY NOZZLES TO COVER
the
wheel from the
LOWER HUB
to the
TOP ONE.
Turn OFF your dilution station. Consult your MCWW