Thomson
Thomson PC-Series™ Precision Linear Actuator - Installation Manual - June 2014
8
4.5 Mounting of the unit using the mounting holes
All PC-Series actuators have mounting holes in the front plate while the parallel style also have mounting
holes in the rear plate on the belt gear. The mounting holes can be used to attach the unit to the support
or to the mounting accessories designed for the purpose (see point 4.7). Make sure to follow the general
mounting guidelines (see point 4.4) when using the mounting holes.
4.5.1 Mounting of the unit using the front plate mounting holes
See below drawings for hole pattern, size and thread depth of the front mounting holes. Note that the
mounting holes on PC32 and PC40 has a 14 mm long unthreaded part before the thread starts.
PC25
PC32
PC40
4.5.2 Mounting of the unit using the rear plate mounting holes on parallel style units
See below drawings for hole pattern, size and thread depth of the rear mounting holes.
PC25 PC32 PC40
Mounting hole size Total mounting hole depth [mm] Outer unthreaded depth [mm]
Inner threaded depth [mm]
PC25
M3
14
0
14
PC32
M6
44
14
30
PC40
M6
44
14
30
Mounting hole size
Mounting hole thread depth [mm]
PC25
M5
8
PC32
M6
8
PC40
M6
8